• Amerigo Scientific Instrument

    Immunohistochemistry (IHC) is a powerful technique for detecting the localization and relative expression levels of specific antigens in cells and tissues through the specific binding between antibodies and antigens. The advent of antigen retrieval methods allows IHC to be performed conveniently on frozen tissues, formalin fixed paraffin embedded (FFPE) tissues, and tissues fixed with other aldehydes. The selection of a fixation method needs to match the type of tissue used for the desired experimental outcomes. Frozen tissues and acetone fixation tissues show good antigen unmasking, while FFPE tissue samples are amenable to easy storage and preserve good cell morphology.

    The first step in IHC is usually antigen retrieval (AR), which retrieves antigens masked by prolonged or excessive fixation and makes antigens more accessible to antibody binding. The most popular methods are heat induced AR (HIAR) and enzyme-based AR. The steps following AR are the sequential addition of a primary antibody, a secondary antibody bound to the primary antibody, and a detection reagent used to localize the primary antibody. Colorimetric and fluorescent are currently two main types of IHC staining. Colorimetric IHC forms a colored precipitate at the site of antibodies binding to antigens and is typically used for qualitative experiments. Fluorescent IHC uses fluorophore-conjugated antibodies to localize antigen-antibody complexes and is preferable for quantitative and multi-label experiments.

    Nonspecific background staining is one of the major hurdles for optimal IHC detection and can be caused by both exogenous and endogenous factors such as nonspecific antibody binding and endogenous enzyme activity. In general, nonspecific binding can be decreased by pre-incubation with normal serum from the same species as the secondary antibody or with a universal blocking agent. Endogenous enzyme activity can be inhibited by pretreating the tissue with solutions containing hydrogen peroxide prior to addition of the antibody.

    Amerigo Scientifics offers high-quality antibodies, antigen retrieve solutions, blocking buffers, detection kits, and more to assist you in obtaining reliable IHC results with high sensitivity, specificity and reproducibility, whether you utilize fluorescent or chromogenic detection, single or multiple labeling, or direct and indirect methods.

    Products (412)
    Sort by: Cat. No.
    Show (10) per page
    FIS 8330
    • Size: 2lb. Bag (8/Case)
    • Catalog Number: IHC1441736MER
    • Application: Embedding, Infiltration
    MCC 502004
    • Size: 1kg/bag (8 bags/case)
    • Catalog Number: IHC1441735MER
    MCC 501006
    • Size: 1kg/bag (8 bags/case)
    • Catalog Number: IHC1441734MER
    MCC 503002
    • Size: 1kg/bag (8 bags/case)
    • Catalog Number: IHC1441733MER
    CES CF101500
    • Size: 10mL, 500 Vials
    • Catalog Number: IHC1441732MER
    CES CR102G
    • Size: 4x1L
    • Catalog Number: IHC1441731MER
    CES CF101G
    • Size: 4x1000mL/Case
    • Catalog Number: IHC1441730MER
    FIS 22110678
    • Size: 10mL Vials, (12 Vials/Case)
    • Catalog Number: IHC1441729MER
    MER 14796500ML
    • Size: 500mL
    • Catalog Number: IHC1441728MER
    • Application: H&E Staining, Manual Staining
    MER 147961L
    • Size: 1 Liter
    • Catalog Number: IHC1441727MER
    • Application: H&E Staining, Manual Staining
    Online Inquiry

    Note: If you don't receive our verification email, do the following:

  • Copyright © Amerigo Scientific. All rights reserved.