MicroStacker™ Detection Kits are immunohistochemistry (IHC) detection tools based on micro-polymer stacking technology. They are developed by integrating core technologies including micro-polymer scaffolds, HRP stacking, Fab' labeling, and advanced conjugation chemistry.
Amerigo Scientific offers MicroStacker™ Detection kits that are biotin-free secondary antibody conjugation systems designed for the detection of primary antibodies on tissues during the IHC process (regular IHC, multiplex IHC, and intraoperative frozen-section IHC). By eliminating the need for streptavidin or biotin, it effectively avoids non-specific staining.
MicroStacker™ technology enables precise control over the layered stacking of F(ab') fragments of IgG secondary antibody and peroxidase enzymes onto a micro-polymer scaffold.

| Product | MicroStacker™ Polymer Detection Kit, Universal | MicroStacker™ Polymer Detection Kit, Enhanced |
|---|---|---|
| Advantages | High sensitivity, stable reagents. | Compared to MicroStacker™ Universal, the Enhanced detection achieves higher sensitivity because the additional amplification step further amplifies the primary antibody signal. |
| Applications | Suitable for manual IHC detection of mouse and rabbit antibodies in paraffin-embedded tissues. | Suitable for manual IHC detection of mouse and rabbit antibodies in paraffin-embedded tissues. Suitable for low-expression antigens and low-affinity antibodies. |
| Staining Procedure | Primary Ab Incubation: RT, 60 min; Secondary Ab Incubation: RT, 30 min; DAB Incubation: 5 min |
Primary Ab Incubation: RT, 30 min; Signal Amplification: RT, 30 min; Secondary Ab Incubation: RT, 30 min; DAB Incubation: 5 min |
| Application Example | ![]() HER2 (Rabbit mAb) on Breast Tissue |
![]() HER2 (Rabbit mAb) on Breast Tissue |
| Product | MicroStacker™ Flex HRP-Polymer Detection Kit | MicroStacker™ Plus HRP-Polymer Detection Kit |
|---|---|---|
| Advantages | Flexible selection of post-primary amplifiers to further enhance staining results | The increased polymerization of enzymes and antibodies, achieving higher sensitivity and faster staining (saving approx. 35 min) |
| Applications | Automated IHC staining for CNT300/CNT330 equipment | Automated IHC staining for CNT360 equipment |
| Staining Procedure | Primary Ab Incubation: RT, 30min; Signal Amplification: RT, 20min; Secondary Ab Incubation: RT, 20min; DAB: 5min. |
Primary Ab Incubation: RT, 20min; Signal Amplification: RT, 8min; Secondary Ab Incubation: RT, 8min; DAB: 5min. |
| Application Example | ![]() P40 on Lung Squamous Cell Carcinoma Tissue |
![]() MUC2 on Intestinal Tissue |
MicroStacker™ Rabbit-on-Rodent HRP-polymer detection kit is mainly used for the staining of rabbit monoclonal/polyclonal antibodies on mouse/rat tissues. MicroStacker™ goat anti-rabbit HRP-polymer detection kit and MicroStacker™ goat anti-mouse HRP-polymer detection kit are respectively used for the detection of rabbit monoclonal/multiclonal antibodies and mouse monoclonal/polyclonal antibodies in human tissues. MicroStacker™ Mouse-on-Mouse polymer detection kit is used for the superior detection of mouse primary antibodies on mouse tissue, providing lower background and clearer staining compared to conventional methods.
| Product Name | Staining Procedure |
|---|---|
| MicroStacker™ Rabbit-on-Rodent HRP-Polymer Detection Kit | Primary Ab Incubation: RT, 60min Secondary Ab Incubation: RT, 30min DAB Incubation: 5min |
| MicroStacker™ Goat Anti-Rabbit HRP-Polymer Detection Kit | |
| MicroStacker™ Goat Anti-Mouse HRP-Polymer Detection Kit | |
| MicroStacker™ Mouse-on-Mouse Polymer Detection Kit | Primary Ab Incubation: RT, 30-60 min Secondary Ab Incubation: RT, 12 min DAB Incubation: 5 min |