Streptavidin Coated PCR Plates

Streptavidin Coated PCR Plates

Catalog Number:
LC01530786BIO
Mfr. No.:
PCR9601/2/30STF-SA5/100 / 100/W
Price:
  • Size:
    Quantity:
    Add to Cart:
      • Overview
        • Streptavidin Coated PCR Plates are made in clear polypropylene coated with different molecules for your needs. Their thin walls optimize the heat transfer from the block to the reaction solution. while the rim of the wells is designed to protect against cross-contamination, allowing a reliable seal with the sealing mats tailored to the plates.

          · PCR plates are pre blocked with standard proteic blocking (ELISA Blocking)
          · Recommended working volume of 50 to 100 μl
          · Each coated plate is packed in a single barrier bag with desiccant

          Surface
          Streptavidin coated surface on Streptavidin Coated PCR Plates offers a powerful and universal instrument for binding any biotinylated molecule (Proteins-Peptides-Polysaccharides-Oligonucleotides-DNA fragments-etc.) finding a special application for those molecules which do not offer reliable bonding by passive adsorption or adsorb in an unfavourable orientation.

          Please contact us at for specific academic pricing.

          Background

          Streptavidin Coated Surface is a powerful and universal instrument for binding any biotinylated molecule.
          Streptavidin is the most popular and widely available biotin-binding protein for research methods. It is a tetrameric protein (M.W. 60 kDa) with very high affinity for biotin (Ka=10-15 M). Biotin is a small molecule which can be conjugated to many proteins without losing or altering their activity. Each protein can bind many biotin molecules. The bond is the strongest known non-covalent biological interaction.

          The Streptavidin Coating is a surface treatment that allows to bind any biotinylated molecule (Antibodies – Antigens – Proteins – Peptides – Polysaccharides – Oligonucleotides – DNA fragments etc.). It finds a special application for those molecules which do not offer reliable bonding by passive adsorption or adsorb in an unfavorable orientation. For example, Streptavidin Coated Plates are suitable with ELISA assays protocol.

          Each subunit of Streptavidin binds one molecule of Biotin giving at Streptavidin Coated Surface a greater assay sensitivity. Streptavidin-Biotin binding main features are specificity, stability, and affinity.

          · Streptavidin Coated Surfaces main features
          Biomat's Streptavidin Coated plates and tubes have the following characteristics:
          Ready to use
          Manufactured under ISO:9001 guidelines
          Post-coated (blocked) for low non specific binding and long-term stability
          All lots are tested for uniformity and reproducibility
          Certificate of Quality is released for every lot
          For Research Use Only

          Also, Streptavidin Coated Products ensures:

          Uniformity
          The Streptavidin Coated products show a CV% less than 5 using biotin-HRP as detector and TMB as substrate.

          Storage and Stability
          The Streptavidin coated products, if unopened, are stable at 2-8°C until the expiration date printed on the label. If opened, store in closed pouch with desiccant and use within the expiration date.

          · Streptavidin Coated Microplates Specifications
          Coating
          Streptavidin is coated using 200 µl/well.

          · Streptavidin Coated Plates parameters and functional features
          The following parameters were analysed to determine the functional features of the Streptavidin coated plates,

          Binding capacity towards Biotin.
          Specificity towards Biotin.
          Binding capacity towards Biotinylated IgG.
          Stability tests:
          Endurance under strong chemical contacts.
          Shelf life at 37°C.
          Temperature stress (transport simulation).
          Long storage.
          Binding capacity towards Biotin.

          1. Binding capacity towards Biotin
          Streptavidin coated wells (and BSA saturated control wells) were incubated with a calibrated Biotin solution. Subsequently, aliquots of this solution, concomitantly with Biotin standards, were mixed with biotinylated peroxidase and transferred into new empty Streptavidin coated wells. From the amount of enzyme bound to the solid phase, the Biotin content of the samples was calculated.

          This value was compared with the amount of biotin originally added; from the difference (corrected for-non specific binding of biotin to the control wells), the capacity of the wells for biotin was derived.

          2. Specificity towards biotin
          Streptavidin Coated Wells were incubated with solutions of biotinylated peroxidase and non biotinylated peroxidase (blanks) as a catcher in a ELISA format using TMB as substrate.

          3. Binding capacity towards biotinylated HIgG
          Streptavidin coated wells were incubated with biotinylated HIgG in an ELISA format using HIgG-HRP as a detector and TMB as substrate.

          4. Stability tests
          Endurance under strong chemical contacts

      • Properties
        • Other Properties
          Material: High Quality Polypropylene
          Format: Non-skirted, Semi-skirted, Skirted
          Volume: 0.2 ml
          Surface: Streptavidin
          Coating volume: 100 µl
          Blocking: Non proteic, Standard
          Shelf life: 1 year
          Unit: 5 pcs
          Minimum order: 10 pcs
          Packaging: Qty/bag: 1
          Storage
          2 – 8°C

          * For research use only.

      • Applications
        • Application Description
          Development of a ultra-high-throughput molecular assay to detect SARS-CoV2 fir population-level screening.
          Surface based tagmentation.