Seplife® RP LXMS 30 Reversed Phase Resin (DVB)

Seplife® RP LXMS 30 Reversed Phase Resin (DVB)

Catalog Number:
CM01530348SUN
Mfr. No.:
PS00042X(30)2-x
Price:
  • Size:
    Quantity:
    Add to Cart:
      • Overview
        • Highly uniform particle size for high resolution

          Styrene/divinylbenzene non functionalized resin characterized by high hydrophobicity

          Suitable for RPC in the separation of proteins, peptides, oligonucleotides and other small and medium size biomolecules
          Seplife® RP LXMS 30 is a polymeric resin for reversed phase chromatography (RPC) characterized by strong chemical stability and high rigidity for use in polishing steps requiring use of organic solvents and high flow rates.
          Seplife® RP LXMS 30 is a polymeric resin for RPC based on styrene/divinylbenzene with a highly uniform particle size (30 micron).

          Please contact us at for specific academic pricing.

      • Properties
        • Categories
          Synthetic Chromatography Resins
          Other Properties
          Appearance: White spherical beads
          Matrix: Styrene/Divinylbenzene
          Particle size range (μm): 27-33
          Typical pore size (Å): 300
          pH stability: 1-14
          Chemical stability: Stable in commonly used aqueous buffers 1.0 M HCl, 100% ethanol, 100% methanol, 100% acetone, 1.0 M NaOH, 0.1% TFA in acetonitrile, 100% isopropanol,100% tetrahydrofuran
          Chemical stability: Max 900
          Dynamic binding capacity** (mg/ml): ≥22
          Shipped as: Slurry in 20% ethanol solution

          *Testing conditions: Chromatography column 10mm×200mm; Column bed height 200mm; Packing pressure 4.0 MPa; Mobile phase 100% MeOH.
          **Testing conditions: Chromatography column 4.6mm×250mm; Column bed height 250mm; Packing pressure 4.0 MPa; Mobile phase water; Sample: Vitamin B12; Retention time 2 minutes.

          * For Research Use Only.

      • Applications
        • Application Description
          DAC Column Packing
          Ensure the Seplife® RP LXMS 30 resin is fully dispersed and free of agglomerates; for this purpose shake or roll the bottle with the packing media or ultrasonicate for approximately five minutes. Use the following guideline to pack the chromatographic column:
          (1) Measure the desired mass or volume of homogeneous slurry with about 1.2 times the column volume.
          (2) Replace the 20% ethanol storage solution with 100% methanol or 80% acetonitrile solution and equilibrate overnight.
          (3) Before loading the column, adjust the slurry concentration to 50-70% with 100% methanol or 80% acetonitrile solution, and pour the entire volume of homogenate into the DAC chromatography column.
          (4) Complete the assembly of the column and operate the packing station according to the manufacturer instructions. A piston packing pressure of approximately 0.8-2.0 MPa is recommended. Ensure that the packing pump pressure has been calculated using the correct ratio for the column ID/packing station being used to give a piston pressure.
          (5) Once column packing is complete, the flow of packing solvent is ceased and the pump stopped, allow the column to equilibrate for 10 minutes.
          (6) Lock the column plunger in the compressed position so that the column can be operated in the Static Axial Compression (SAC) mode.
          (7) The packed column is now ready for use. It can be used while still assembled on the packing station or it can be undocked for use in a purification facility .

          Column Efficiency Evaluation
          After packing, clean the chromatographic column with 3-5 CV of 100% methanol or 80% acetonitrile solution. The flow rate should be controlled at 120-180 cm/h to balance and perform column efficiency test.
          The test method for column efficiency of RP chromatography columns is as follows:
          Mobile phase: 100% methanol or 80% acetonitrile solution
          Linear flow rate: 120-180 cm/h
          Sample: 1:9 (v:v) Acetone in 100% methanol or 80% acetonitrile
          Loading volume: 1 % of column volume;
          Detection: UV @ 254 or 280 nm ;
          The prep-HPLC system geometry, including dead volume, will significantly affect the plate count determination.

          Equilibration
          Equilibrate with the mobile phase for 3-4 CV, and control the flow rate at 120-180 cm/h until the conductance and pH of the flow-through remain unchanged before loading the sample.

          Sample feeding
          The solid sample can be prepared by dissolving in the equilibrium solution. Low-concentration sample solutions can be concentrated in advance as much as possible while too high concentration sample solution can be diluted with the equilibration solution. To avoid clogging of the column, samples should be processed by centrifugation or membrane filtration. The feed amount is calculated according to the capacity of the resin and the content of the target protein in the feed solution. Before loading, ensure the sample buffer is as consistent as possible with the equilibration solution.

          Elution
          Use 2-10 CV of methanol, ethanol, acetonitrile, acetone, etc. (aqueous) solution to elute; use acid, caustic or buffer to adjust the pH or use a combination both to elute the molecules of interest.

          Regeneration and CIP
          First use acetonitrile, methanol, ethanol, acetone, NaOH in ethanol or other solvents to wash the column (3-4 CV) according to the operating flow rate, and then use the equilibration solution to rinse (3-4 CV).

          Storage
          Sealed and stored at 4-30°C (preservation solution is 20% ethanol) in a ventilated, dry and clean place, do not freeze.

    Note: If you don't receive our verification email, do the following:

    • Confirm that you entered your email address correctly.
    • Check if the email is in your spam or junk folder.
    • Or you may contact us at .
    Copyright © Amerigo Scientific. All rights reserved.