MICROPACKED-ST

MICROPACKED-ST

Catalog Number:
GMC1110669SHI
Mfr. No.:
GCC139318-MIC02
Price:
$773
  • Size:
    Quantity:
    Add to Cart:
      • Overview
        • With changes in analytical trends, many varieties of packed columns have been replaced with capillary columns. However, because gaseous samples occupy large volumes and easily diffuse at room temperature, there are still a large number of unfavorable factors preventing a complete switch to capillary columns, with the result that many analyses of these kinds of samples still rely on packed columns. MICROPACKED columns used with capillary GC and GC/MS systems enable to analyze samples that are difficult with capillary columns.

          Feature
          ・ MICROPACKED columns boast larger sample capacities than PLOT (Porous Layer Open Tubular) capillary columns.
          ・ Higher levels of column efficiency in comparison with conventional packed columns enable shorter analysis times.

          Handling precautions
          This product is a separation column designed for use in gas chromatographs. Do not use this product for any other purpose. Please read the following precautions in order to use this product correctly.

          Precautions when unpacking this column
          ·Remove the column from its box by pressing down on the round foam rubber sheet located in the center of the column and pulling the column frame towards you. Exercise care when removing the column from its box, as the connection tubes attached to the ends of the column may spring back. When using this column, wear protective equipment including gloves and safety glasses, and exercise care in handling.

          Precautions when using this column
          ·Avoid bending this column excessively. Excessive bending can lead to crushing of the packingmaterial inside the column and emissions of fine particles from the column.
          ·Do not allow kinks to form in the connection tubes attached to each end of this column. Kinks in connection tubes can lead to carrier gas leaks and blockages.
          ·The maximum operating temperature for this column is 330℃. Do not subject this column to temperatures higher than 330℃.
          ·When using this column at a temperature of 70℃ or higher, do not turn off the carrier gas.

          Precautions when connecting this column to gas chromatographs
          ·As with general capillary columns, this column can be connected to gas chromatographs using ferrules. Please use wide-bore capillary column (0.53 mm I.D.) ferrules in order to connect this column.
          ·In the case of gas chromatographs that employ automatic flow controllers or analytical software to control carrier gas flow rates, actual carrier gas flow rates and split ratios, etc. will differ from values displayed. Enter dummy column dimensions (e.g., length: 250 m, inner diameter: 0.5 mm, film thickness: 10 μm) in order to achieve an appropriate level of carrier gas pressure and normal gas chromatograph control (no error outputs). When accurate carrier gas flow rates and split ratios are required, use a flow meter, etc. to measure the gas flow rates from the column and split outlets.

          Please contact us at for specific academic pricing.

      • Properties
        • Categories
          GC Micropacked Columns
          Other Properties
          Material: Stainless steel (SUS)
          Packing material: SHINCARBON ST
          Mesh size: 80-100
          Column dimensions: 2.0 m × 1.27 mm O.D. × 1.0 mm I.D. SUS
          Connection tubes: 0.5 m × 0.52 mm O.D. × 0.30 mm I.D. SUS
          Maximum operating temperature: 330℃
      • Applications
        • Application Description