Boiler/Cooling Systems, Alkalinity/Hardness/Orthophosphate/Sulfite

Boiler/Cooling Systems, Alkalinity/Hardness/Orthophosphate/Sulfite

Catalog Number:
WTKS494374TAY
Mfr. No.:
TWT-K-1645-1
Price:
$382
  • Size:
    kit
    Quantity:
    Add to Cart:
      • Overview
        • We have responded with an expansive selection of professionally manufactured specialty test kits for every job. With industry-leading innovation and quality built into every kit, there is never a need to own multiple test kits or reagents that you won’t use. You’ll never have to choose between accuracy and convenience-they’re always packaged together, in every water test kit.

          Please contact us at for specific academic pricing.

      • Properties
        • Details
          Analyte System Method/Chemistry Standard/Equivalance or Description Comparator Cell
          Orthophosphate Two-Standard comparator Stannous chloride 30 & 60 ppm PO₄³⁻ 9025 9021
          Alkalinity, P/M & P/T Drop test Phenolphthalein/methyl orange/blended indicator 1 drop = 10 ppm P/M or P/T alkalinity as CaCO₃ NA 9198G
          Hardness, Total Drop test EDTA titration (includes inhibitors to prevent metal interference) 1 drop = 10 ppm total hardness as CaCO₃ NA 9198B
          Sulfite (Sodium) Drop test Iodometric 1 drop = 10 ppm Na₂SO₃ NA 9198W
          Storage
          All reagents have a shelf life, whether they are liquids, powders, crystals, tablets, or test-strip pads. If kept dry, powders and crystals are very stable; acids are also long lived. Date of manufacture is not the controlling factor when it comes to shelf life-storage conditions are more important. As with all perishables, reagents are sensitive to environmental influences and will last longer under controlled conditions.

          To this end, we recommend:
          • Storing reagents at a consistent temperature in the range if 36°-85°F (2°-29°C); extreme temperature fluctuation, say from a refrigerator to a hot car trunk, causes reagents to deteriorate.
          • Keeping them out of prolonged direct sunlight. (Note: their brown plastic bottles help protect very light-sensitive reagents.)
          • Segregating reagents from containers of treatment chemicals.
          • Replacing caps immediately and tightening them carefully so that exposure to air and humidity is limited.
          • Avoiding switching bottle caps, placing bottle caps on soiled surfaces, repouring reagents into contaminated containers, or touching test strip pads.

          We formulate reagents to remain effective for at least one year, with only very few exceptions (molybdenum indicator in liquid form is one; after four months old it should be tested against a standard periodically). As a general precaution, replace all reagents more than one year old, or at the beginning of a new testing season.
          Research Field
          Market: Industrial

          * For research use only.

      • Applications
        • Application
          Boiler/Cooling Tower
          Application Description
          Test Parameter Description
          Erythorbic acid, sulfide and ferrous iron may cause positive interference; to prevent, test for suspected interfering agent, dilute sample with DI water as necessary, and retest. Copper and nitrite may cause negative interference; to prevent, test for suspected interfering agent, dilute sample with DI water as necessary, and retest. Delay between taking sample and testing may cause negative interference; to prevent, perform test immediately after sample is taken. Quats may cause interference by forming a precipitate and causing a yellow endpoint. Sulfite
          Silica, ferrous iron, fluoride, and sulfide may cause interference; to prevent, test for suspected interfering agent, dilute sample with DI water as necessary, and retest. Orthophosphate
          High halogen level may change indicator reaction from green/red to blue/yellow; to prevent, add thiosulfate prior to testing. Filming amines, quats, and biguanides may interfere and cause the endpoint to look purple; to prevent, add 10 drops of R-0884 prior to testing. Alkalinity
          Metal ions may cause interference; to prevent, add titrant containing EDTA to sample before buffer and indicator, then test as normal making sure to count drops of titrant added initially in total required to reach endpoint. If interference still occurs, dilute sample with DI water as necessary and retest. Quats may cause interference. Hardness

    Note: If you don't receive our verification email, do the following:

    Copyright © Amerigo Scientific. All rights reserved.