      • Overview
        • The Titanium Standard for ICP; ICP-MS 10;000 µg/mL (10;000 ppm) in 20% Hydrochloric Acid (HCl) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. The hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances.
          - GHS/OSHA compliant, REACH
          - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.

          Please contact us at for specific academic pricing.

      • Properties
        • Categories
          Conductivity Standards; ICP-OES, ICP-MS Standards and Reagents; Physicochemical Standards
          Appearance
          Liquid
          Other Properties
          Additional Information: Ultrapure
          Analyte: Titanium (Ti)
          Country of Origin: Ireland
          Features: 10,000 µg/mL (10,000 ppm)
          Matrix: 20% HCl
          Hazard Information
          3.2/2 Causes skin irritation.3.3/2A Causes serious eye irritation.4.1.A/3 Harmful to aquatic life.4.1.C/3 Harmful to aquatic life with long lasting effects.P280 Wear protective gloves/protective cloth
          • H Statements:
          3.1.O/5 MAY BE HARMFUL IF SWALLOWED.3.1.I/5 MAY BE HARMFUL IF INHALED.

          * For Research Use Only.

      • Applications
        • Application
          with ICP, ICP-MS, AA, IC, XRF and other Cation Measurement Techniques