Tellurium Standard for ICP, ICP-MS 100 µg/mL (100 ppm) in 20% Hydrochloric Acid (HCl)

Tellurium Standard for ICP, ICP-MS 100 µg/mL (100 ppm) in 20% Hydrochloric Acid (HCl)

Catalog Number:
ES02464315CYM
Mfr. No.:
07-PTE1A10
Price:
$271
  • Size:
    100ml
    Quantity:
    Add to Cart:
      • Overview
        • The Tellurium Standard for ICP; ICP-MS 100 µg/mL (100 ppm) in 20% Hydrochloric Acid (HCl) for ICP or ICP-MS is manufactured from ultra-pure metal (99.999%). This product is manufactured gravimetrically using the mass balance approach: 100% less the sum of all impurities (w/w). Prior to bottling; the final product is tested and verified using ICP-MS and is reported using the gravimetric result; corrected for density. To a specification of ± 0.2%. The results are reported in mg/kg and mg/L on the basis of weight and density. The hold ISO 17025 accreditation (A2LA Ref: 6739.02) for calibration of laboratory balances.
          - GHS/OSHA compliant, REACH
          - This product is produced in a highly controlled cleanroom (ISO 7) environment, using ultra-pure water (specially treated for the production of mass spectroscopy standards), triple distilled acids and triple leached pre-cleaned bottles. The titrimetry and spectroscopy are controlled and calibrated using separate standards, so the product comes with two layers of traceability including NIST Standards, where available. All of the uncertainties of measurement for this product are calculated according to Eurachem/CITAC guidelines and reported as expanded uncertainties at the 95% confidence level.

          Please contact us at for specific academic pricing.

      • Properties
        • Categories
          Conductivity Standards; ICP-OES, ICP-MS Standards and Reagents; Physicochemical Standards
          Appearance
          Liquid
          Other Properties
          Additional Information: Ultrapure
          Analyte: Tellurium (Te)
          Country of Origin: Ireland
          Features: 100 µg/mL (100 ppm)
          Matrix: 20% HCl
          Hazard Information
          3.1.O/4 Harmful if swallowed.3.1.D/3 Toxic in contact with skin.3.1.I/5 May be harmful if inhaled.3.2/1B Causes severe skin burns and eye damage.3.3/1 Causes serious eye damage.P260 Do not breathe dus
          • H Statements:
          3.2/1B CAUSES SEVERE SKIN BURNS AND EYE DAMAGE.3.3/1 CAUSES SERIOUS EYE DAMAGE.

          * For Research Use Only.

      • Applications
        • Application
          with ICP, ICP-MS, AA, IC, XRF and other cation measurement techniques