RCM Re-scanning Confocal Microscope

RCM Re-scanning Confocal Microscope

Catalog Number:
GLE1505993SIN
Mfr. No.:
SIN240018AM
Price:
  • Size:
    EA
    Quantity:
    Add to Cart:
      • Overview
        • RCM adds the combination of Unit 1 (Confocal microscope) and Unit 2 (Re-scanner + CCD) to a conventional microscope and updates it to be a higher-resolution confocal microscope. It can capture datasets of 170nm resolution raw (120 after deconvolution) over a very large FOV. Study fast live-cell dynamics and perform 3D imaging in optimized conditions.
          Sharp images, a large field of view and easy to use? It's possible with Confocal.nl. Get more from your samples, with a higher resolution and a higher sensitivity than conventional confocal microscopes and study live samples longer. Our Re-scanning Confocal Microscope (RCM) uses multiple laser pointers and a camera as a detector. The low laser power required is live cell friendly: it prevents phototoxicity in your live samples and photobleaching of your fluorophores. Creating long-term time lapses at a super-resolution was never this accessible.
          RCM2 is our second-generation RCM, with digital scanner technology. It makes re-scanning the standard and allows a speed of 2fps at 512×512 pixels. RCM2 has optics to make it suitable for super-resolution imaging with high NA objectives in the low magnification range, like 40 x 1.4. A lower magnification allows for a bigger field of view (FOV), brighter images, and even lower laser power. RCM2 has demonstrated imaging at 10 nano-watt excitation power!
          Improvements of sCMOS cameras allow you to sample resolution of low magnification objectives effectively, without increasing the exposure time. In a regular PMT-based confocal this is not possible.

          The Benefits of RCM2
          · Using RCM2 with a 40x 1.4 objective, you can see more cells at full resolution at once. A larger field of view increases the chances of getting the results you need.
          · Obtain sharp images with a high signal-to-noise ratio even in samples with a low amount of epitopes or weak stainings. Get more from your samples.
          · Use even lower laser power to minimize phototoxicity and photobleaching during live-cell imaging.
          · Getting super-resolution raw images, without averaging or integration, reduces the acquisition time and allows for a more precise analysis of the subcellular structures.

          Please contact us at for specific academic pricing.

      • Properties
      • Applications
        • Application Description
          Capture datasets of 170nm resolution raw (120nm after deconvolution) over a very large FOV. Study fast live-cell dynamics and perform 3D imaging in optimized conditions. The increased detection efficiency facilitates acquisition in low fluorescence conditions, like single-molecule detection (smFISH). In combination with silicon objectives, RCM2 allows for deep 3D imaging of organoids, zebrafish embryos, or larger live samples.