Overview
-
ITALO 600 is a fully automated, high efficiency solution for chemistry testing clinics/labs offering the ultimate improvements in performance, con- venience and reliability. At optimal configuration, it performs 640 tests/hour (1000 tests/hour with ISE), providing high quality testing for medium to big sized laboratories.
ITALO 600 test menu allows for complete consoli- dation of routine and special tests on an efficient and user friendly platform.
Assay methods: End Point, Kinetic, Fix time etc.
Principle: Photoelectric Colorimetry
Light Source: Halogen lamp 12 V/20W
Photometry range: 0~3.2Abs Resolution: 0.0001Abs
Wavelength: 12 wavelengths (340 nm, 405 nm, 450 nm, 480 nm, 505 nm, 546 nm, 570 nm, 60 5nm, 660 nm, 700 nm, 750 nm, 800 nm) using grating
Throughput: Constant 640 tests/h, 1000 tests/h with ISE
Reagent tray: 160 reagent positions
Sample tray: 99 sample positions, including detergent position, standard positions, QC positions, STAT positions
Reaction tray: 120 reaction positions
Sample volume: 2~100 uL, with 0.1 uL increment
Reagent volume: 5~1000 uL, with 0.5 uL increment
Minimum reaction volume: 150 uL
Maximum reaction time: 10 minutes
Water Consumption: less than 25 L/hour under working status
Clean unit: 8-steps auto-washing system
Calibration: Calibration reset, select best test point by reaction curve, no need second calibration
Control rules: Westgard multi-rule, Cumulative Sum check, Twin plot
Temperature control: incubator 37 ± 0.1 °C
Power supply: AC 220 (1±10%) V, 50Hz
Ambient: Operating temperature: 10~35X
Relative humidity: ≤85%
Atmospheric pressure: 86~106 k Pa
FEATURES
• 8-steps auto-washing system with detergent and 37°C water
• 24 hour non-stop water cycle cooling system to ensure reagent at 2-8°C
• Three-unattached durable ceramic syringes
• Incubation system with solid collision protection in both vertical and horizontal directions
• Alarm & Stop automatically once touching barrier, not to affect former tests
• Automatic eligible cuvettes detection & selection
• Select best test point by reaction curve, create new factor automatically
WASHING STATIONS
8 stages washing system with washing solution and pure water wash steps
REACTION SYSTEM
120 semi-permanent cuvette Solid direct heating system Minimum reaction volume: 100 μL
SAMPLING SYSTEM
Collision protection Liquid level detection Precise syringe
OPTICAL SYSTEM
12 wavelengths high accuracy, close, static state grating optical system Spot photometry with high speed digital transmission system High quality light source ensure 2000 hours lifespan Water cooling system. Stand-by modePlease contact us at for specific academic pricing.
-