Goat Anti-Mouse/Rabbit Multiplex IHC Detection Kit (Quintuple)

Goat Anti-Mouse/Rabbit Multiplex IHC Detection Kit (Quintuple)

Catalog Number:
IHC1447889ZEN
Mfr. No.:
Zen-18006
Price:
  • Size:
    100T
    Quantity:
    Add to Cart:
      • Overview
        • Please contact us at for specific academic pricing.

          Background

          Tyramide Signal Amplification (TSA) is a kind of enzymatic detection method that uses horseradish peroxidase (HRP) to label target proteins. Similar to the DAB chromogenic method of conventional immunohistochemistry, TSA also uses HRP-labeled secondary antibody that HRP catalyzes the tyramide fluorescein substrates added to the reaction system to generate activated fluorescent substrates, which can be covalently bound to residues such as tyrosine on the antigen. Therefore, the sample can be stably bound to tyramide fluorescein. The covalently attached protein cannot be washed off, even if the slides are treated to remove the antibodies, since the tyramide bond is covalent. The non-covalently bound antibody-HRP complex can be washed away by heat-induced epitope retrieval, and new antibody-HRP complex is repeated in the next round of incubation with another tyramide fluorescein substrate, thus achieving multiple-labeling.

          Protocol:
          1. After antigen retrieval to secondary antibody incubation, the TSA Dye (added TSA Enhancer) should be incubated about 10-15 min at RT in dark. Wash the slides 3 x 5 min in PBS.
          2. Repeat steps from antigen retrieval to TSA Dye reaction until all kinds of tyramide fluorescein substrates are incubated. Wash the slides 3 x 5 min in PBS.
          3. Mount using compatible mounting medium and add a coverslip.

      • Properties
        • Categories
          Multiple IHC staining kits
          Formulation
          Reagent 1: Goat anti-Mouse/Rabbit HRP polymer
          Reagent 2: TSA Enhancer
          Reagent 3: TSA-520 Dye (Ex: 488nm / Em: 520nm)
          Reagent 4: TSA-570 Dye (Ex: 555nm / Em: 570nm) Reagent 5: TSA-620 Dye (Ex: 590nm / Em: 620nm)
          Reagent 6: TSA-690 Dye (Ex: 630nm / Em: 690nm) Reagent 7: TSA-780 Dye (Ex: 750nm / Em: 780nm)
          Storage
          Refer to the instructions

          * Research Use Only Product (RUO). Not for Diagnosis or Therapeutic Use.

      • Applications
        • Application
          IHC-P
          Application Description
          Each Reagent is 100μl/T (TSA Enhancer : TSA Dye = 1 : 500)

    Note: If you don't receive our verification email, do the following:

    • Confirm that you entered your email address correctly.
    • Check if the email is in your spam or junk folder.
    • Or you may contact us at .