CyFlow™ CD3 FITC

CyFlow™ CD3 FITC

Catalog Number:
A001343534SYS
Mfr. No.:
AB614014
Price:
$456
  • Size:
    100 tests (2.0 mL)
    Quantity:
    Add to Cart:
      • Overview
        • Please contact us at for specific academic pricing.

          Background

          CD3 complex is crucial in transducing antigen-recognition signals into the cytoplasm of T cells and in regulating the cell surface expression of the TCR complex. T cell activation through the antigen receptor (TCR) involves the cytoplasmic tails of the CD3 subunits CD3γ, CD3 δ, CD3ε and CD3ζ. These CD3 subunits are structurally related members of the immunoglobulins superfamily encoded by closely linked genes on human chromosome 11. The CD3 components have long cytoplasmic tails that associate with cytoplasmic signal transduction molecules. This association is mediated at least in part by a double tyrosine-based motif present in a single copy in the CD3 subunits. CD3 may play a role in TCR-induced growth arrest, cell survival and proliferation. The CD3 antigen is present on 68-82% of normal peripheral blood lymphocytes, 65-85% of thymocytes and Purkinje cells in the cerebellum. It is never expressed on B or NK cells. Decreased percentages of T lymphocytes may be observed in some autoimmune diseases.

      • Properties
        • Host
          mouse
          Antibody Type
          monoclonal
          Isotype
          IgG1
          Reactivity
          human; non-human primates
          Clone
          UCHT1
          Immunogen
          Human thymocytes followed by Sezary T cells
          Conjugate
          FITC
          Formulation
          The reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.09% (w/v) sodium azide.
          Storage
          Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
          Regulatory Status
          RUO
          Antigen
          Leu4, T3

          * Research use only

      • Applications
        • Application
          Flow Cytometry
          Application Description
          The reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 20·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (2 ml) is sufficient for 100 tests.

          Emission Maximum: 518 nm
          Excitation Maximum: 490 to 495 nm