Gas Chromatography Mass Spectrometry LZ-GCMS-A879

Gas Chromatography Mass Spectrometry LZ-GCMS-A879

Catalog Number:
GLE1316015LAB
Mfr. No.:
LZ-GCMS-A879
Price:
  • Size:
    Each
    Quantity:
    Add to Cart:
      • Overview
        • Gas Chromatography Mass Spectrometry LZ-GCMS-A879 is a high precision Gas chromatograph mass spectrometer with pre-filter mass analyzer and electron multiplier ensuring high sensitivity. Desorption for solids is performed at controlled temperature between 100 ~ 350 °C with a flow rate of 1 to 1.5 ml / min. With seven stage temperature programming and an interface temperature of 450 °C the analysis is sensitive and specific.

          Features
          • Column flow rate is 1 ~ 1.5 ml / min
          • Maximum flow rate is 10 ml / min
          • Simultaneous analysis with different components increasing productivity
          • Electronic flow control system
          • Mass analyzer with pre-filter reducing quadruple filtration
          • Turbo molecular pump vacuum system for stability and reliability
          • Software controlled auto sampler , gas chromatograph and mass spectrometer
          • Screens and quantifies more than 1000 compounds in a single run

          Please contact us at for specific academic pricing.

      • Properties
        • Categories
          Chromatography
          Other Properties
          Gas Chromatography Specifications
          Flow rate: 1 ~ 1.5 ml / min
          Maximum Flow rate: 10 ml / min
          Inlet temperature: 450 °C
          Pressure range: 0 ~ 100 psi
          Heating rate: Up to 120 °C / min
          Room temperature: 4 °C ~ 450 °C
          Pressure control mode: Electronic pressure control ( Supports CV and CC )
          Split mode: Split / split less
          Split ratio: 41.667361111111
          Temperature programming: 7 stages / 8 platforms
          Auto sampler: Optional
          Mass Spectrometry Specifications
          Mass range: 1.5 ~ 1000 amu
          Ion-Source temperature: 100 °C ~ 350 °C
          GC-MS Interface temperature: 450 °C
          Scan rate: Up to 10000 amu/s
          Stability: ± 0.10 amu / 48 hrs.
          Filament emission current: 0 ~ 350 µA
          EI Source ionization energy: 5 eV ~ 250 eV
          Resolution: Unit resolution
          Detector: High energy dynode electron multiplier
          Sensitivity: Full scan ( S / N is ≥ 30 : 1 )
          Vacuum: Turbo molecular pump ( 67 L/s )

          * For research use only

      • Applications
        • Application Description
          Used in identifying and quantifying volatile organic compounds in mixtures, testing residual solvents, identification of trace impurities in liquids or gases, evaluating extracts from plastics, contaminants on semiconductor wafers or other technology products.