          Background

          The specificity of staining by monoclonal antibodies to target antigens should be verified by establishing the amount of non-specific antibody binding. Especially at higher concentration (more than 15 μ/ml) the antibody staining usually has consignable background. To this end a non-reactive immunoglobulin of the same isotype is included as a negative control for each specific monoclonal antibody used in a particular immunoassay. The monoclonal antibody MOPC-173, generated against an undefined antigen, does not react specifically with mouse, rat and human samples, and hence all the background that could be observed when working with this antibody would be a result of general nonspecific interactions between an mouse IgG2a molecule and the respective sample under the particular conditions. This shall help the customer to set up the experimental conditions so that the nonspecific binding of any antibody is abolished.

      • Properties
        • Host
          mouse
          Antibody Type
          monoclonal
          Isotype
          IgG2a
          Clone
          MOPC-173
          Immunogen
          The transplantable plasmacytoma MOPC-173 was induced by intraperitoneal injection of mineral oils into BALB/c mice
          Conjugate
          Alexa-fluor®-488
          Formulation
          The reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.09% (w/v) sodium azide.
          Storage
          Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
          Concentration
          0.1 mg/mL
          Regulatory Status
          RUO

          * Research use only

      • Applications
        • Application
          Flow Cytometry (isotype control)
          Application Description
          The reagent is designed as an isotype control for Flow Cytometry analysis. To establish the amount of non-specific antibody binding, match the concentration of the correct isotype to the recommended working concentration of the antigen-specific antibody. If the background signal of the isotype control is too high (usually when working antibody concentrations are above 10·µg/ml of incubation mixture), change the experimental conditions to reduce the background.

          Emission Maximum: 519 nm
          Excitation Maximum: 495 nm