Afla-V ONE Lateral Flow Strip Test for Measuring Aflatoxin

Afla-V ONE Lateral Flow Strip Test for Measuring Aflatoxin

Catalog Number:
M001556119VIC
Mfr. No.:
176005106
Price:
  • Size:
    25 Tests
    Quantity:
    Add to Cart:
      • Overview
        • Afla-V™ ONE offers the world’s first lateral flow strip test capable of measuring total aflatoxins (B1, B2, G1 & G2) in complete feeds and pet foods. Using a simple, barcode-based universal calibration, Afla-V™ delivers numeric results in minutes while improving safety and sustainability for field, process and laboratory testing environments. Afla-V ONE eliminates toxin-dependent calibration completely, reduces time to result and offers unmatched performance for aflatoxin monitoring in finished feeds.

          Benefits
          • Safe – Eliminates toxic calibration chemicals
          • Value – No hidden costs or sample batching required
          • Fast screening – Actionable results in 5 minutes*
          • Sensitive – Limits of detection as low as 2 ppb
          • Wide range – 0 to 300 ppb†
          • Convenient – Easily performed onsite or in the lab
          • Accurate – Results equivalent to HPLC methods
          • Durable – Long shelf life
          *compared with traditional rapid and laboratory methods
          **after extraction † Using high range procedure

          Please contact us at for specific academic pricing.

          Background

          Aflatoxin, a toxin from a naturally occurring mold, is a Group 1 carcinogen proven to cause cancer in humans. The United States federal government action level for aflatoxin in food for human consumption or in dairy cowfeed is 20 ppb. For milk for human consumption the level is 0.5 ppb. Levels up to 300 ppb are allowed in certain circumstances for nondairy animal feed. The European Union’s aflatoxin regulations for groundnuts, tree nuts, dried fruit, spices, and cereals include limits as low as 4 ppb total aflatoxins and 2 ppb for aflatoxin B1. Some EU member states have also separately established their own maximum limits on aflatoxins.

      • Properties
        • Categories
          Lateral Flow Strip Tests

          * For Research Use Only.

      • Applications
        • Application Description
          • Weigh sample
          • Add Extraction Solution
          • Blend
          • Transfer sample to test vial containing diluent
          • Mix well, transfer 100 µL to Afla-V test strip
          • Incubate the Test Strip for 5 minutes
          • Insert the test strip into Vertu TOUCH Reader
          • Read results

    Note: If you don't receive our verification email, do the following:

    • Confirm that you entered your email address correctly.
    • Check if the email is in your spam or junk folder.
    • Or you may contact us at .