CyFlow™ CD29 APC

CyFlow™ CD29 APC

Catalog Number:
A001343461SYS
Mfr. No.:
CA236759
Price:
$488
  • Size:
    100 tests (1.0 mL)
    Quantity:
    Add to Cart:
      • Overview
        • Please contact us at for specific academic pricing.

          Background

          CD29 (β1 integrin subunit, GPIIa) forms non-covalently linked heterodimers with at least 6 different α chains (α1-α6, CD49a-f) determining the binding properties of β1 (VLA) integrins. These integrins mediate cell adhesion to collagen, fibronectin, laminin and other extracellular matrix (ECM) components. This interaction hinders cell death, whereas disruption of anchorage to ECM leads to apoptosis. Decreased expression of most β1 integrins correlates with acquiring multidrug resistance of tumor cells during selection in presence of antitumor drug. In platelets, translocation of intracellular pool of β1 integrins to the plasma membrane following thrombin stimulation. These integrins are also up-regulated in leukocytes during emigration and extravascular migration and appear to be critically involved in regulating the immune cell trafficking from blood to tissue, as well as in regulating tissue damage and disease symptoms related to inflammatory bowel disease. Through a β1 integrin-dependent mechanism, fibronectin and type I collagen enhance cytokine secretion of human airway smooth muscle in response to IL-1β.

      • Properties
        • Host
          mouse
          Antibody Type
          monoclonal
          Isotype
          IgG1
          Reactivity
          dog; human; pig
          Clone
          MEM-101A
          Immunogen
          Raji cells: human Burkitt's lymphoma cell line
          Conjugate
          APC
          Formulation
          The reagent is provided in stabilizing phosphate buffered saline (PBS) solution, pH ≈7.4, containing 0.09% (w/v) sodium azide.
          Storage
          Avoid prolonged exposure to light. Store in the dark at 2-8°C. Do not freeze.
          Regulatory Status
          RUO
          Antigen
          Integrin β1

          * Research use only

      • Applications
        • Application
          Flow Cytometry
          Application Description
          The reagent is designed for Flow Cytometry analysis of human blood cells. Recommended usage is 10·µl reagent·/ 100·µl of whole blood or 10^6 cells in a suspension. The content of a vial (1 ml) is sufficient for 100 tests.

          Emission Maximum: 660 nm
          Excitation Maximum: 650 nm

    Note: If you don't receive our verification email, do the following:

    Copyright © Amerigo Scientific. All rights reserved.