Lifecask™ RW Single-Use Bioreactor Bags
| Cat. No. | Specification | Unit | Price | Quantity |
|---|---|---|---|---|
| BAF1504283-01 | 2L | each | Inquiry |
|
| BAF1504283-02 | 10L | each | Inquiry |
|
| BAF1504283-03 | 20L | each | Inquiry |
|
| BAF1504283-04 | 50L | each | Inquiry |
|
Product Description
Product Description
Lifecask™ RW Single-Use Bioreactor Bags are specially designed for a rocking mode bioreactor. It is sterilized by gamma irradiation and packaged in double PE bag to avoid cross-contamination. The bioreactor bags are manufactured with our self-produced Lifemeta™ KA film to ensure a good mechanical performance as well as biocompatibility. Lifecask™ RW Single-Use Bioreactor bags can be widely applied to multiple upstream process of bio-pharmaceuticals such as antibody, vaccine and CGT. Apart from the basic bag configuration, we launched RW PRO features integrated pH and DO optical sensors, and RW Perfusion with an integrated retention membrane to satisfy multiple culture modes such as seed train expansion, fed-batch or perfusion processes. What's more, fabric carriers or microcarriers can also be applied to the bags for adherent cell culture.
Specifications
| item | Results (After Gamma irradiation>25kGy) | Procedure |
| Haze | 21.20% | ASTM D1003 |
| Specular Gloss | 118 GU | ASTM D2457 |
| Color | SCI: L 94.06, a -0.27, b 2.89 SCE: L 90.50, a -0.43, b 2.33 | ASTM D6290 |
| Transmittance | 90.20% | ASTM D1003 |
| Tensile Strength at Break | Transverse 219 Lengthways 267, bar | ASTM D882 |
| Elongation at Break | Transverse 380 Lengthways, 420% | ASTM D882 |
| Elastic Modulus | Transverse 2770 Lengthways 2890, bar | ASTM D882 |
| Brittleness Temperature by impact | Below -70°C | ASTM D1790 |
| Density | 0.941 g/cm³ | ASTM D792 |
| Dart Impact | 1398 g | ASTM D1709 Method B |
| Peak load | 178 N | ASTM D3763 |
| Deflection at peak load | 13.6 mm | ASTM D3763 |
| Tear Strength | Transverse 37.5 Lengthways 34.7, N | ASTM D1004 |
| Puncture Resistance | 52.2 N | ASTM F1306 |
| Water Vapor Transmission Rate | 0.593 g/(m²·day) (23°C, 100% RH) | ASTM F1249 |
| Oxygen Permeability | 1.024 cm³/(m²·day·bar) | ASTM D1434 |
| Carbon Dioxide Permeability | 1.455 cm³/(m²·day·bar) | ASTM D1434 |
| Particulate Matter | Particulate matter in the product eluent meets the requirements in USO<788> for larger volume parenterals. | |
| USP<87> Cytotoxicity | Meet the requirement of USP<87> in Vitro Biological Reactivity Test. | |
| USP<88>Biological Reactivity | Meet the criteria of USP<88>Biological Reactivity Test for Class VI plastics. | |
| Indirect Food Addictive | The fluid contact component materials meet the FDA Indirect Food Addictive requirements cited in 21 CFR 177-182. | |
| Animal Derivative Content | Products do not contain animal derived components and are free from TSE risk. | |
| Quality Assurance | These products are manufactured in a facility which adheres to ISO®9001:2015 Practices. | |
Applications
Application Description
Suspension Cell Culture: CHO, HEK293, BHK21, Hybridoma, SF9
Suspension cell perfusion culture (Cell Retention Membrane/Hollow Fiber)
Adherent cell culture: HEK 293, Vero, etc.
Suspension cell perfusion culture (Cell Retention Membrane/Hollow Fiber)
Adherent cell culture: HEK 293, Vero, etc.
Related Products
Online Inquiry
Note: If you don't receive our verification email, do the following:
- Confirm that you entered your email address correctly.
- Check if the email is in your spam or junk folder.
- Or you may contact us at .