| Cat. No. | Dimensions (WxDxH) | Specification | Unit | Price | Quantity |
|---|---|---|---|---|---|
| BAF1552101-01 | W680×D480×H914 mm (Main unit) | Temp. accuracy: ±0.3 °C (37 °C); Max. shaft stroke: 40 mm; Max. shaft speed: 150 mm/s | Each | Inquiry |
|
| Item | Specifications | ||||
|---|---|---|---|---|---|
| Name | HiD4×4 | ||||
| Model | HiD4-4 | ||||
| Temp. control device | Hot plate + chiller / heating & cooling type (PID control) with over-temperature protection function | ||||
| Power transmission | Linear shaft drive non-sealing type | ||||
| Performance*1 | Temp. control range | Room temperature + 5 - 20 [°C] (normally set to 37 [°C]) | |||
| Temp. accuracy | ±0.3 [°C] (37 [°C]) | ||||
| Max. shaft stroke | 40 [mm] | ||||
| Max. shaft speed | 150 [mm/s] | ||||
| Function | Temp. setting | Touch panel input, data output DC1 - 5 [V] | |||
| Vertical motion setting | Touch panel input, (option : mixing frequency data output DC0 - 5 [V] ) | ||||
| Configuration | Power of hot plate | 235 [W]×4 | |||
| Chiller | Cooling type, 450 [W], HFC R-404A | ||||
| Power of motor | Max. output 800 [W] | ||||
| Mixing impeller | VM200 | ||||
| Culture tank | Dimensions | I.D. 94/87 x Depth 110 [mm] | |||
| Culture operation volume | 0.25 - 0.3 [L] | ||||
| Usage condition | 10 - 35[°C] | ||||
| Outer dimensions | Main unit (HiD4×4) | W680×D480×H914 [mm] | Chiller (SCA-32) | W205×D405×H545 [mm] | |
| Weight | Main unit (HiD4×4) | Approx. 70 [kg] | Chiller (SCA-32) | Approx. 28 [kg] | |
| Power supply | AC100 [V], 50/60 [Hz] | ||||
| *1 The performance is the value under room temperature 20 [°C], power supply AC100 [V], 50 [Hz] and no load condition. | |||||
| Item | Specifications | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Name | Culture controller | ||||||||||||||||
| Model | S-BOX×02 | ||||||||||||||||
| Control | pH, DO (Dissolved oxygen) | ||||||||||||||||
| Display range/accuracy | pH (Hydrogen ion concentration) | 0.00 - 14.00 [-] | Display accuracy: ±0.5 [%] F.S. | ||||||||||||||
| DO (Dissolved oxygen) | 0.00 - 20.00 [mg/L] | ||||||||||||||||
| Setting range | pH (Hydrogen ion concentration) | 0.00 - 14.00 [-] | |||||||||||||||
| DO (Dissolved oxygen) | 0.00 - 20.00 [mg/L] | ||||||||||||||||
| Control type | pH (Hydrogen ion concentration) | CO2ON/OFF control | |||||||||||||||
| DO (Dissolved oxygen) | O2ON/OFF control | ||||||||||||||||
| Data output | pH (Hydrogen ion concentration) | With data logger DC0 - 5 [V] (option : Mixing frequencyand Load factor can be outputted.) |
Accuracy: ±0.5 [%] F.S. | ||||||||||||||
| DO (Dissolved oxygen) | |||||||||||||||||
| Temperature sensor | With data logger DC1 - 5 [V] | ||||||||||||||||
| MTA of outer surface | SUS304 (no coating) , indoor type, non-waterproof, non-explosion proof specification | ||||||||||||||||
| Installation | Indoor stand-alone type | ||||||||||||||||
| Outer dimensions/weight | W600×D500×H914 [mm] *Does not include protrusions approx. 70 [kg] | ||||||||||||||||
| Usage conditions | Temperature | 5 - 45 [°C] | Humidity | 20 - 85 [%] RH (No condensation) | |||||||||||||
| Sensors | Polarographic DO sensor/pH sensor manufactured by Mettler Toledo company | ||||||||||||||||
| (Option: Optical DO sensor manufactured by Automatic System Research Co., Ltd.) | |||||||||||||||||
| Utilities | Power supply | AC100 [V], 50/60 [Hz], electrical outlet 2 gang (for main control unit, and laptop) | |||||||||||||||
| N2 | Flow rate 50 [mL/min] or lower, supply pressure 0.2 [MPa], connection port φ6 one touch tube fitting | ||||||||||||||||
| O2 | Flow rate 50 [mL/min] or lower, supply pressure 0.2 [MPa], connection port φ6 one touch tube fitting | ||||||||||||||||
| CO2 | Flow rate 50 [mL/min] or lower, supply pressure 0.2 [MPa], connection port φ6 one touch tube fitting | ||||||||||||||||
| AIR | Flow rate 150 [mL/min] or lower, supply pressure 0.2 [MPa], connection port φ6 one touch tube fitting | ||||||||||||||||
| *All of N₂, O₂, CO₂, and AIR must be dry and clean gases that do not contain corrosive components, dust, and oil mist. | |||||||||||||||||
| Item | Specifications | |||||||||
|---|---|---|---|---|---|---|---|---|---|---|
| Data gathering module GM10 |
Material | Polycarbonate | ||||||||
| Outer dimensions | W45.1×H111×D107.1[mm] | |||||||||
| Weight | approx. 0.25[kg] | |||||||||
| Power supply | From GM90PS power supply module | |||||||||
| Power consumption | 2.8 [W] or less | |||||||||
| Power supply module GM90PS |
Material | Polycarbonate | ||||||||
| Rated voltage | AC100-240[V] | |||||||||
| Outer dimensions | W88×H135×D126.7[mm] | |||||||||
| Weight | approx. 0.55[kg] | |||||||||
| module base GM90MB |
Material | Polycarbonate | ||||||||
| Outer dimensions | W57.7×H135×D103.5[mm] | |||||||||
| Weight | approx. 0.15[kg] | |||||||||