TCE-N300A, Compact Thermostatic Chamber for Autograph Precision Universal Testing Machines
| Cat. No. | Specification | Unit | Price | Quantity |
|---|---|---|---|---|
| MTI1503403-01 | Chamber Inner Dimension - Height: 725 mm | EA | Inquiry |
|
| MTI1503403-02 | Chamber Inner Dimension - Height: 850 mm | EA | Inquiry |
|
| MTI1503403-03 | Chamber Inner Dimension - Height: 600 mm | EA | Inquiry |
|
Product Description
Product Description
The thermostatic chamber controls the temperature in the testing space, enabling tensile, bending, and compression tests under a variety of temperature conditions.
Features
• The temperature can be set using special software
• Thermostatic chamber positioning is easy
• Thermostatic chamber positioning is easy
Specifications
Main Unit - 125 mm Extension Type
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Rail Type: 76 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 725 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Rail Type: 1420 to 1850 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 132.5 mm below and above the center
Main Unit - 250 mm Extension Type
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Rail Type: 82 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 850 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Rail Type: 1550 to 1980 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 155 mm below and above the center
Main Unit - Standard Height
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Caster Type: 80 kg
Rail Type: 70 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 600 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Caster Type: 1405 to 1815 mm
Rail Type: 1300 to 1730 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 110 mm below and above the center
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Rail Type: 76 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 725 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Rail Type: 1420 to 1850 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 132.5 mm below and above the center
Main Unit - 250 mm Extension Type
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Rail Type: 82 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 850 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Rail Type: 1550 to 1980 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 155 mm below and above the center
Main Unit - Standard Height
Temperature Usage Range *1 *2: -70 to +300°C
Weight: Caster Type: 80 kg
Rail Type: 70 kg
Temperature distribution: Minimum to maximum for three measurement locations is within 3°C
Temperature Stability *4 *5: Within ±2°C
Temperature Decrease Rate *4: 25 minutes from room temperature to -70°C
Temperature Increase Rate *4: 25 minutes from room temperature to 300°C
Power Capacity: 2.7 kVA for 200 V; 3.5 kVA for 230 V
Power requirement: Single-phase 200 to 230 V, 50/60 Hz
Chamber Inner Dimension - Height: 600 mm
Heating system: Heater
Chamber Inner Dimension - Depth: 300 mm
Chamber Inner Dimension - Width: 300 mm
External Dimensions - Height: Caster Type: 1405 to 1815 mm
Rail Type: 1300 to 1730 mm
External Dimensions - Depth: Caster Type: 860 mm; Rail Type: 1280 mm
External Dimensions - Width: Caster Type: 680 mm; Rail Type: 410 mm
Cooling System *3: Liquid Nitrogen Gas Spray
Temperature Distribution Measurement Points *6: Three points: The center of the thermostatic chamber, and 110 mm below and above the center