PFAT All-teflon Corrosion Resistance Filter

Cat. No. Specification Unit Price Quantity
FCM1504362-01 Membrane: Hydrophobic polytetrafluoroethylene (PTFE) each Inquiry

Add to Cart

Product Description
Product Description
Quality:
· 100% Integrity testing in manufacturing
· Each filter is fully traceable with unique serial number
· Manufactured in a facility which adheres to ISO 9001:2015 Practices
Features
· 100% all fluoropolymer construction
· Excellent chemical compatibility
· 100% integrity testing to ensure the integrity of the cartridge
· Better resistance to high temperature and pressure
· High flow rate
· Low differential pressure
· Low leachables
Specifications

Materials of Construction

Membrane Hydrophobic polytetrafluoroethylene (PTFE)
Support Polyfluoroalkoxy (PFA)
Core/Cage/End Caps Polyfluoroalkoxy (PFA)
End Cap Inserts 316L (With FSSC, FSSF, FSTC) End Caps
Seal Material Silicone / EPDM / Viton
FEP/ PFA encapsulated O-rings


Operating Conditions

Max. Operating Temperature
80°C
Max.Operating Pressure
0.69 MPa@25°C
0.40 MPa@60°C
0.24 MPa@80°C
Max. Differential Pressure (Forward)
0.69 MPa@25°C
0.40 MPa@60°C
0.24 MPa@80°C
Max. Differential Pressure (Reverse)
0.30 MPa@25°C
0.10 MPa@80°C


Filtration Area

Outer Diameter Membrane Pore Size Area/10'
68 mm 0.2 μm
0.91 m²


Integrity Standard @10inch, 20°C

Membrane Pore Size Bubble Point Diffusion Flow(Air)
0.22 μm ≥ 0.10 MPa, 60% IPA 40% Water, Air test
/


Bacterial Retention

Model Content
0.2 μm Bacterial quantitative retention of 10⁷ cfu/cm² Brevundimonas diminuta(ATCC19146)according to ASTM F838 methodology


Sterilization

In-line steam sterilization
Up to 15 cycles (135°C for 30 min and differential pressure < 30 kPa per cycle)
Autoclave
Up to 120 cycles (130°C for 30 min per cycle)

*Only FSS, FSSF and FSTC end cap can be in-line steam sterilized.



Regulatory Compliance

  • Autoclaved filter effluent meets the USP<788> requirement of particulate matter in large volume injection.
  • Component materials meet the criteria for a' Non-fiber-releasing filter' as defined in 21 CFR 210.3(b)(6).
  • Aqueous extraction from a cartridge contains less than 0.25EU/ml as determined by Limulus Amebocyte Lysate (LAL), meeting requirements of USP<85>.
  • Meet the requirement of USP <87> In Vitro Cytotoxicity Test.
  • Component materials meet the requirements of the current USP<88> for plastic class VI-121°C.
  • All component materials meet the FDA Indirect Food Additive requirements cited in 21 CFR 177-182.
  • Based on the current information from our suppliers, all component materials used in the manufacture of this product are animal-free.
Ordering Information:
Outer Diameter Type Pore Size End Cap Nominal Length Seal Material Industry
68mm PFAT 0020   0.20 µm SF   226/Fin (not support In-line steam sterilization) 03   3 inch S   Silicone C


SC   226/Flat (not support In-line steam sterilization) 04   4 inch E   EPDM P

TC   222/Flat (not support In-line steam sterilization) 10   10 inch K   PTFE

FSSC   226/SS Insert Flat
            (support In-line steam sterilization)
20   20 inch P   FEP/PFA encapsulated O-rings

FSSF   226/SS Insert Fin
            (support In-line steam sterilization)


FSTC   222/SS Insert Flat
            (support In-line steam sterilization)


* Example: PFAT0020SF03SC (PFAT, 0.20µm, 226/Fin(not support In-line steam sterilization), 3 inch, Silicone, Industrial)
Applications
Application Description
Ozone filtration
Filtration of strong oxidising solvents, strong acids and bases, organic solvents
Related Products

Online Inquiry

Note: If you don't receive our verification email, do the following:

GET IN TOUCH
7x24

Seamless access to cutting-edge products and services with our professional support.

Copyright © Amerigo Scientific. All rights reserved.