Julie Z10 Fulmatic™ is calibrated according to established standard methods for milk analysis:
· Roesse Gottlieb – for fat
· Kieldahl – for protein
· HPCL – for lactose
· Oven drying – for total solids
· Cryoscopy – for freezing point
Cat. No. Dimensions (WxDxH) Unit Price Quantity
OPI1531085-01 48 x 45 x 38 cm Each Inquiry

Add to Cart

Product Description
Product Description
Julie Z10 is capable of analyzing a wide variety of milk and dairy products with exceptional accuracy and unprecedented repeatability of the measured results.

Thanks to its innovative Nano-Optics measuring system, built-in printer, 8" touch screen, and the SE Data Collection software it is the best milk analyzer that we can offer.

· Julie Z10 – Calibrations
Julie Z10 has three calibration banks.
It can be calibrated for three products. One of the calibrations is factory-made free of charge and the other two are offered as paid add-ons upon customer's request.
Specifications
Measured Parameters:
Parameter: Fat
Accuracy (Resolution): 0.0001
Range: 0.00% - 60.00%
Consistency (Repeatability): ±0.01

Parameter: SNF
Accuracy (Resolution): 0.0001
Range: 0.00% - 60.00%
Consistency (Repeatability): ±0.01

Parameter: Protein
Accuracy (Resolution): 0.0001
Range: 0.00% - 25.00%
Consistency (Repeatability): ±0.01

Parameter: Lactose
Accuracy (Resolution): 0.0001
Range: 0.00% - 25.00%
Consistency (Repeatability): ±0.01

Parameter: Density
Accuracy (Resolution): 0.00001
Range: 1.0150-1.0400 g/Sm3
Consistency (Repeatability): ±0.01

Parameter: Solids
Accuracy (Resolution): 0.0001
Range: 0.00% – 5.00%
Consistency (Repeatability): ±0.01

Parameter: Freezing Point
Accuracy (Resolution): 0.001°C
Range: -0.45°C to 0.55°C
Consistency (Repeatability): ± 0.001°C

Parameter: Added water
Accuracy (Resolution): 0.0001
Range: 0.00%- 80%
Consistency (Repeatability): 0.0001

Parameter: PH
Accuracy (Resolution): 0.0001
Range: 0.00 - 14 PH
Consistency (Repeatability): ±0.01

Parameter: Conductivity
Accuracy (Resolution): 0.0001
Range: 0.00 - 10Ms/sm
Consistency (Repeatability): ±0.01

Sample volume: 10 ml /5 ml for human calibration
Sample temperature: 2 to 45°C
Humidity: 0 to 80°C
Database Processing: USB (SEDataCollection)
Dimensions (W x D x H): 48 x 45 x 38 cm
Weight: 18 kg
Power supply: 12V = 6A, 85W
Applications
Application Description
Julie Z10 can be calibrated for:
· Cow milk
· Sheep milk
· Goat milk
· Buffalo milk
· Human milk
· Pasteurized milk
· UHT milk
· Cream with up to 50% fat content
· Yogurt with freshly added culture
· Coconut milk
· Fruit milk
· Yakult
· Skimmed milk
· Powdered milk
· Soy milk
· Whey
· Ice cream mixtures