HPTLC-Densitometer CD60

The CD60 densitometric scanner is the most complete tool in its class for characterizing samples after HPTLC migration.
Qualifications and quantifications are carried out quickly and easily thanks to its ergonomic, dedicated software.
This versatile, high-performance instrument guarantees optimum results whatever the molecules analyzed.

Advantages:
SST (system suitability test) can be done using our HPTLC system.
The TLC/HPTLC system can be hyphenated with any company make TLC-MS interface.
All TLC/HPTLC products can work under the GLP/GMP environment.
We use validated and certified software to run the TLC/HPTLC system.
Cat. No. Dimensions (WxDxH) Unit Price Quantity
C002490739-01 300x730x550mm EA Inquiry

Add to Cart

Product Description
Product Description
The HPTLC-Densitometer CD60 includes the know-how of more than 20 years experience and the current state of the art. A PC serves as interface between the user and the CD60 and controls all functions of the densitometer. It is equipped for absorbency and fluorescence measurements in reflectance and transmittance on objects with dimensions up to 265x200x4mm.

Three light sources are provided: a deuterium lamp (190 – 340nm), a halogen lamp (340-900nm) as well as a mercury lamp. The usable spectral range extends from 190 to 900nm whereby the monochromator, the lamps and the filters are automatically switched over. The size of the scanning light beam can also be adjusted by the PC. Slit widths from 0.4 to 10mm and slit heights from 20µm to 2mm are possible. There are many application possibilities in conjunction with the software ProQuant. This extraordinary software operating under Windows 10 is also easy to use by those without computer experience, so that its use can be learned in very short time. Process chromatograms and compile result and peak lists in a simple, reliable manner that conforms with GxP! You rapidly acquire reproducible results and data of real evidential worth.

• The software Proquant of the HPTLC-Densitometer CD60 takes on the informations from the HPTLC-Applicator AS30 software.
• A PC is used to control absorption and fluorescence measurements in transmission and remission.
• Both detectors are part of the basic equipment.
• An additional reference photomultiplier measures the light intensity of the active lamp and automatically adjusts sensitivity.
• There are three integrated light sources: a deuterium lamp, a halogen lamp and a mercury lamp.
• The monochromator offers a useful spectrum between 190 and 900nm, and enables automatic switching of lamps and filters.
• It features automatic background correction and a device for eliminating unwanted artifacts (fingerprints, scratches, stains) from the measurement.
• It can analyze each sample with 30 wavelengths simultaneously. In this way, each molecule gives a maximum signal at its specific wavelength.
• Highly efficient for trace detection, it identifies unknown molecules by comparing them with pre-recorded spectra.
• Used in conjunction with ProQuant software, this densitometer is suitable for a wide range of applications.
• The densitometer-computer combination enables chromatograms to be processed and results to be recorded easily, securely and in compliance with GLP standards.
• This guarantees reproducible results and reliable data.
• It is equipped with ProValidR software for validations and ProQuantR software for spectra and molecule quantification based on pre-recorded calibration curves.
• The CD60 Densitometer complies with CF21 Part 11 (optional).
Specifications
• Dimensions (DxHxW): 300x730x550mm
• Weight: 30kg
• Filters: 370, 420, 450, 550, orange, UV
• Max scan length: 5 to 195mm
• Maximum scan width: 5 to 260mm
• Spectral range: 190-900mm