| Cat. No. | Dimensions (WxDxH) | Specification | Unit | Price | Quantity |
|---|---|---|---|---|---|
| DF01556175-01 | 385×330×(405+155) mm³ | Tmax in °C: 1100 | Each | Inquiry |
|
| DF01556175-02 | 385×390×(460+205) mm³ | Tmax in °C: 1100 | Each | Inquiry |
|
| DF01556175-03 | 415×455×(515+240) mm³ | Tmax in °C: 1100 | Each | Inquiry |
|
| DF01556175-04 | 415×555×(515+240) mm³ | Tmax in °C: 1100 | Each | Inquiry |
|
| DF01556175-05 | 290×280×430 mm³ | Tmax in °C: 1200 | Each | Inquiry |
|
| DF01556175-06 | 385×330×(405+155) mm³ | Tmax in °C: 1200 | Each | Inquiry |
|
| DF01556175-07 | 385×390×(460+205) mm³ | Tmax in °C: 1200 | Each | Inquiry |
|
| DF01556175-08 | 415×455×(515+240) mm³ | Tmax in °C: 1200 | Each | Inquiry |
|
| DF01556175-09 | 415×555×(515+240) mm³ | Tmax in °C: 1200 | Each | Inquiry |
|
| Model | Tmax | Inner dimensions in mm | Volume | Outer dimensions2 in mm | Temperature uniformity of +/− 5K in the empty workspace5 | Max. connected load | Electrical | Weight | Heating time | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| in °C1 | w | d | h | in l | W | D | H3 | w | d | h | in kW | connection* | in kg | in min4 | |
| L(T) 3/11 | 1100 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.3 | 1-phase | 20 | 40 |
| L(T) 5/11 | 1100 | 200 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 90 | 2.6 | 1-phase | 30 | 50 |
| L(T) 9/11 | 1100 | 230 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.3 | 1-phase | 35 | 65 |
| L(T) 15/11 | 1100 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.5 | 1-phase | 40 | 75 |
| L 1/12 | 1200 | 90 | 115 | 110 | 1 | 290 | 280 | 430 | 45 | 60 | 40 | 1.6 | 1-phase | 10 | 25 |
| L(T) 3/12 | 1200 | 160 | 140 | 100 | 3 | 385 | 330 | 405+155 | 110 | 50 | 50 | 1.3 | 1-phase | 20 | 45 |
| L(T) 5/12 | 1200 | 200 | 170 | 130 | 5 | 385 | 390 | 460+205 | 170 | 80 | 90 | 2.6 | 1-phase | 30 | 60 |
| L(T) 9/12 | 1200 | 230 | 240 | 170 | 9 | 415 | 455 | 515+240 | 180 | 150 | 120 | 3.3 | 1-phase | 35 | 75 |
| L(T) 15/12 | 1200 | 230 | 340 | 170 | 15 | 415 | 555 | 515+240 | 180 | 250 | 120 | 3.5 | 1-phase | 40 | 85 |
| 1Recommended working temperature for processes with longer dwell times is 1000 °C (L../11) rsp. 1100 °C (L../12)*These furnaces are available for main voltage of 110 V - 120 V 2External dimensions vary when furnace is equipped with additional equipment. Dimensions on request.(up to 1,5 kW) resp. 200 V - 240 V, 1/N/PE or 2/PE 3Including opened lift door (LT models) 4Heating time of the empty and closed furnace up to Tmax −100 K (connected to 230 V 1/N/PE rsp. 400 V 3/N/PE) 5Temperature uniformity of +/− 5 K with closed fresh-air inlet in empty work space according to DIN 17052-1 at working temperatures above 800 °C | |||||||||||||||
Maximum Chargeable Number of Burnout Muffles
The table below indicates the maximum number of burnout out muffles that can be charged in our different muffle furnaces.
| Model | Muffle type | |||
|---|---|---|---|---|
| Size 1 x (Ø 37 mm) | Size 3 x (Ø 55 mm) | Size 6 x (Ø 72 mm) | Size 9 x (Ø 88 mm) | |
| LE 1/11 | 6 | 4 | 1 | 1 |
| LE 2/11 | 8 | 6 | 2 | 2 |
| LE 6/11 | 20 | 9 | 4 | 2 |
| LE 14/11 | 35 | 20 | 12 | 6 |
| LE 24/11 | 56 | 28 | 16 | 9 |
| L 1/12 | 6 | 4 | 1 | 1 |
| L(T) 3/.. | 12 | 6 | 2 | 2 |
| L(T) 5/.. | 20 | 9 | 4 | 2 - 3 |
| L(T) 9/.. | 36 | 16 | 9 | 4 |
| L(T) 15/.. | 54 | 24 | 12 | 6 |
Note: If you don't receive our verification email, do the following:
Seamless access to cutting-edge products and services with our professional support.