Automated ELISA 4-Plate System

Cat. No. Dimensions (WxDxH) Specification Unit Price Quantity
OPI1578951-01 39” x 31” x 32.25” Footprint: 10.5 sq ft; Bench Weigh: 270 lbs; Ship Weight: 537 Ibs (max); Noise Output: < 70 dB EA Inquiry

Add to Cart

Product Description

Product Description
With our open platform, fully automated 4-plate system, you can process multiple assays simultaneously and handle samples with the speed and accuracy your lab requires. Advanced automation features provide extraordinary flexibility at every workflow stage.

Product Details

Software
Controlling Software: DSX® Revelation
Work Protocols (Assays): Unlimited
Data Processing: Quantitative and qualitative
Levey-Jennings: Yes
Westgard Rules: Yes
Process Reporting: Event log + error log
Automatic Error Recovery: Yes
Password Access Control: Yes

Specifications

Supply Requirements
Voltage: 100 – 240 V automatic conversion
Frequency: 50/60 Hz
Power Consumption: < 800 VA (online UPS recommended)

System Specifications
Number of Plates: 4
Sample Capacity: 98
Continuous Sample Loading: Yes
Sample Tube Size: 10 – 16 mm diameter / 40 – 100 mm height
Number of Reagents: Up to 24 (25 mL tubes)
Number of Standard/Control Bottles: 33 (1.5 mL vials)
Assays per Plate: Up to 12
Dilution Wells Capacity: Up to 192 deep-well strips (24 x 8)
Sample Tip Capacity: 432 tips (4 x 108)
Reagent Tip Capacity: 41 tips

Reader Specifications
Photometric Range: 0.000 – 3.500 OD
Spectral Range: 405 – 690 nm
Filter Slots: 6 wavelength
Precision: ± 0.01 OD at 0.000 – 0.500 OD
< 1% CV (< 2.0 OD)
< 1.5% CV (2.0 – 2.5 OD)
Accuracy: ± 0.01 OD or 2.5%
(0.000 – 3.000 OD) whichever is greater
Read Time: < 10 sec (single wavelength)
< 20 sec (dual wavelength)

Washer Specifications
Manifold Configuration: 8-channel wash head
Programmable Volumes: 50 – 999 μL
Wash Buffer Capacity: 4 wash bottles at 2.0 L, with level-sensing
Residual Wash Volume: < 3 μL per well with dual-axis sweep in a flat-bottom plate
Dispense Precision: ≤ 5% CV (with 300 μL in a 96 well plate)
Waste Container Capacity: 8 L with waste full sensor

Incubator Specifications
Number of Incubators: Up to 4
Temperature Range: RT + 7° – 50°C (elevated incubator)
RT + 5°C (ambient incubator)
Temperature Accuracy: ± 1°C
Shaking: > 15 Hz (periodic or continuous)
Temperature Monitoring: Yes

Reagent Pipetting Specifications
Reagent Tip Size: 1,300 μL
Reagent Pipetting Volume: 20 – 1,000 μL
Reagent Pipetting Precision: ≤ 3% CV at 10 shots at any operating volume above 50 μL
Reagent Pipetting Accuracy: ± 2% of target volume at 50 μL or greater operating volume (single-shot mode)

Sample Pipetting Specifications
Sample Tip Size: 300 µL
Sample Pipetting Volume: 10 – 300 µL
Sample Pipetting Precision: ≤ 3% CV at any operating volume above 10 µL (single-shot mode)
Sample Pipetting Accuracy: ± 2% of target volume at any operating volume above 10 µL
Estimated Cycle Time for Sample
Pickup to Delivery on Plate: < 8 sec
Time to Dispense: 19 minutes (typical)
50 μL of 96 samples to plate from sample tubes or deep-well plates
Sampling Time with Dilutions: < 26 minutes (typical)
Dilution Range: 1 part in 190 one-stage dilution
1 part in 36,100 two-stage dilution

Process Security
Liquid Level Sensing: Yes (reagents, controls and samples)
Level Sensor System: Pressure differential
Clot Detection: Yes
Dispense Anomaly Detection: Yes
Tip Detection: Yes
Electronic Signature Pipetting: Yes
Alarms: Yes