6ft Horizontal Laminar Flow Cabinet
Laminar Flow Cabinet is a work bench or similar enclosure, which creates a particle-free working environment by taking air through a filtration system and exhausting it across a work surface in a laminar or unidirectional air stream. The laminar flow cabinet is enclosed on the sides and kept under constant positive pressure in order to prevent the infiltration of contaminated room air.
| Cat. No. | Dimensions (WxDxH) | Specification | Package | Unit | Price | Quantity |
|---|---|---|---|---|---|---|
| LFH1504040-01 | 1800×820×2070 mm | HEPA Filter: 99.999% efficiency at 0.3um | 1950×1060×1600 mm | EA | $2,040 |
|
Product Description
Product Description
A laminar flow cabinet or tissue culture hood is a carefully enclosed bench designed to prevent contamination of semiconductor wafers, biological samples, or any particle sensitive materials. Air is drawn through a HEPA filter and blown in a very smooth, laminar flow towards the user. Due to the direction of air flow, the sample is protected from the user but the user is not protected from the sample. The cabinet is usually made of stainless steel with no gaps or joints where spores might collect.
Features
· Great for COVID-19 specimen handling
· HEPA filters
· Large LCD display
· Easy-to-clean stainless steel chamber
· HEPA filters
· Large LCD display
· Easy-to-clean stainless steel chamber
Product Details
Note
Caution! Installation requires a forklift or a crane.
Attention! Steps before and after using the unit.
· Step 1: Fully close the front glass panel, turn on UV light for 30 mins (you can use the timer setting). Users should leave the room during this disinfection period.
· Step 2. Raise the glass panel to recommended opening height, turn on air circulation for 10 minutes.
· After operation is done, fully close the glass panel, turn on UV light for another 30 minutes, then turn off the unit.
Important Guidelines using a Laminar Flow Cabinet
· No flammable and explosive substances (Building up of flammable material may cause an internal fire or explosion)
· No volatile chemicals (May cause damage to HEPA filters to the point where it allows particles to leak through)
· No toxic chemicals or materials (May reach room occupants)
· No open flame (Will disrupts air flow patterns)
· Minimal use (10mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol is allowed.
Attention! Steps before and after using the unit.
· Step 1: Fully close the front glass panel, turn on UV light for 30 mins (you can use the timer setting). Users should leave the room during this disinfection period.
· Step 2. Raise the glass panel to recommended opening height, turn on air circulation for 10 minutes.
· After operation is done, fully close the glass panel, turn on UV light for another 30 minutes, then turn off the unit.
Important Guidelines using a Laminar Flow Cabinet
· No flammable and explosive substances (Building up of flammable material may cause an internal fire or explosion)
· No volatile chemicals (May cause damage to HEPA filters to the point where it allows particles to leak through)
· No toxic chemicals or materials (May reach room occupants)
· No open flame (Will disrupts air flow patterns)
· Minimal use (10mL or less) of decontaminant, such as 70% isopropyl or ethyl alcohol is allowed.
Specifications
| Model | BBS-H1800 | |
| External Size(W×D×H) | 1800×820×2070mm | |
| Internal Size(W×D×H) | 1700×500×570mm | |
| Work Surface Height | 750mm | |
| Display | LCD Display | |
| Airflow Velocity | Average of 0.3~0.5m/s | |
| Material | Main Body: Cold-rolled steel with anti-bacteria powder coating | |
| Work Table:304 stainless steel | ||
| Side and Front Window: 5mm toughened glass, anti-UV | ||
| Pre-filter | Polyester fiber, washable | |
| HEPA Filter | 99.999% efficiency at 0.3um | |
| Noise | <65dB | |
| Front Window | Motorized | |
| Max Opening | 430mm | |
| LED Lamp | 16W×2 | |
| UV Lamp | 30W×1 | |
| Emission of 253.7 nanometers | ||
| Consumption | 500W | 500W |
| Waterproof socket | Two, total load≤500W | |
| Caster | Universal caster with leveling feet | |
| Power Supply | AC220V±10%, 50/60Hz; 110V±10%, 60Hz | |
| Standard Accessory | LED lamp, UV lamp×2, Base stand, Gas Tap, Waterproof socket×2, | |
| Water Tap (only for BBS-H1800) | ||
| Optional Accessory | Electric height adjustable base stand | |
| Gross Weight | 328kg | |
| Package Size(W×D×H) | 1950×1060×1600mm | |
| Warranty | Three years | |
| Lead Time | About 10 to 15 working days after receive payment | |
Applications
Application Description
Laminar flow cabinet is widely used in medical research laboratories, hospitals, manufacturing facilities and other research and production environments.
Related Products
Laminar Flow Cabinet Compounding Hood
Price: $1,080
Mini Laboratory Laminar Flow Cabinet
Price: $968
Vacuum Drying Oven
Price: $745
Online Inquiry
Note: If you don't receive our verification email, do the following:
- Confirm that you entered your email address correctly.
- Check if the email is in your spam or junk folder.
- Or you may contact us at .