2.2 Ft Class I Biosafety Hood With Hepa Filter And UV Lamp

Cat. No. Dimensions (WxDxH) Specification Package Unit Price Quantity
BC01503784-01 550×395×730 mm HEPA Filter: 99.999% efficiency at 0.3 μm 710×550×950 mm EA $480
BC01503784-02 700×550×900 mm HEPA Filter: 99.999% efficiency at 0.3 μm 870×720×1170 mm EA $960

Add to Cart

Product Description
Product Description
· UV lamp for sterilization.
· Soft touch control panel, LCD display.
· Energy-saving, high efficiency, low noise.
· With memory function in case of power-failure.
· One piece 304 stainless steel work stable, easy for cleaning.
· Stable air flow system; provide firm protection to person and environment.
Product Details
Accessory

Name

Quantity

Position

BYKG-I Main Body

1

Wooden case

Power Line

1

 Packing bag

Fuse Tube(2A)

1

Document pouch

UV Lamp(T8  15W)

1

Paper package

BYKG-I User manual

1

Documents pouch  

Test report

1

Documents pouch

Quality certification card

1

Documents pouch

Warranty Card

1

Documents pouch

Product acceptance certificate and installation report

1

Documents pouch

Training certificate

1

Documents pouch

Note
Installation Notice
Biological safety cabinets should be placed in a position where there should be no opposing wall and far away from ventilation system and air conditioner vent, so as to avoid the airflow impact caused by ventilation system, air conditioner, door, window and even the personnel movement. Also, avoid blocking the local switch door entrance; avoid opposing and placing in the wall corner. There should be at least 300mm of the side of the safety cabinet for checking.
Working environment:
(1) Only is suitable for indoor;
(2) Ambient temperature: 15°C~35°C;
(3) Relative Humidity: ≤75%;
(4) Atmospheric pressure range: 70 kPa~106 kPa;
(5) Electrical parameters: Consistent with the rated voltage of the biological safety cabinet
(6) Power supply need to be grounded; (Judging method: testing the fire wire and the zero line of the power supply with multimeter, the fire wire to ground voltage should be grid voltage and the zero line to ground voltage should be 0, otherwise the power supply ground is bad);
Operation Notice
(1) Make sure input voltage is correct and stable. The rated load of main power socket should be higher than cabinet consumption. Plug must be well grounded;
(2) The weight of items placed in the cabinet should be no more than 15Kg/20×20 cm2;
(3) In order to avoid samples being sucked into the negative passage or the blower, do not place soft and slight samples (for example: soft tissue) on the surface during experiment;
(4) No flame: No flame is allowed inside the cabinet. Using of fire will lead to airflow disorder, and filter damage.
(5) HEPA filter life: With the usage time increasing, dust and bacteria on the filter can lead to efficient filter pressure loss increases, when increases to wind speed cannot meet the requirements, must be timely contact with my company's service department, Please replace new HEPA filter, otherwise it will affect the safety performance of the equipment. The used filter should be processed as medical waste;
(6) There is a negative passage surrounding the work area, which is sealed strictly in the factory. The operator is not allowed to remove or loose screws of those parts. If necessary, please contact service personal;
(7) The maximum storage period is one year. If the period is more than one year, performance test should be done.
Serious declaration: we will take no responsibility for risks caused by improper operation and man-made damages!
Specifications

Model

BYKG-I

BYKG-II

External Size(W×D×H)

550×395×730mm

700×550×900mm

Internal Size(W×D×H)

540×385×440mm

680×540×500mm

HEPA Filter

99.999% efficiency at 0.3 μm

Airflow Velocity

>0.3m/s

0.75~1.0m/s

Noise

≤60dB

≤55dB

Illuminating Lamp

4W×1 

LED Lamp

8W×1

LED Lamp

UV Lamp

15W×1

20W×1

Emission of 253.7 nanometers for most efficient decontamination

Power Consumption

150W

≤160W

Work Surface Height

 /                                           /

Caster

/

Main Body Construction

PMMA

Work Table

304 stainless steel

Power Supply

AC220V±10% , 50/60Hz; 110V±10% ,60Hz

Standard Accessory

LED lamp, UV lamp×2

OptionalAccessory

Electric height adjustable base stand

Gross Weight

38kg

68kg

Package Size(W×D×H)

710×550×950mm

870×720×1170mm

WarrantyOne Year
Applications
Application Description
Class I Biosafety Cabinet does not protect the product from contamination because un-purified room air constantly enters into work area. As a partical containment unit, the Class I Biosafety Cabinet is suitable for work involving low to moderate risk agents (Biosafety Levels 1, 2 and 3) where there is a need for containment, but not for product protection. With the negative pressure, personnel protection is made possible by constant movement of air into the work area.