SSG Series Strain Gauge Extensometers

Cat. No. Specification Unit Price Quantity
MTI1503396-01 Measurement range (mm/FS) : 1.0, 0.5, 0.2, 0.1, Four-step selection EA Inquiry
MTI1503396-02 Measurement range (mm/FS) : 2.5, 1.25, 0.5, 0.25, Four-step selection EA Inquiry
MTI1503396-03 Measurement range (mm/FS) : 5, 2.5, 1.0, 0.5, Four-step selection EA Inquiry

Add to Cart

Product Description
Product Description
Our SSG series of strain gauge extensometers are compliant with ISO, JIS, and ASTM tensile test standards, including those for plastics and metallic materials These lightweight, precision extensometers feature a wide elongation measurement range, while retaining the flexibility to measure using small gauge lengths, and support both rod and flat plate shaped specimens. Consisting of an elongation sensor and amplifier, this extensometer is suitable for use with metals and hard plastic materials, and is fastened securely to specimens with screws. Calibration using an extensometer calibrator allows the extensometer to meet JIS and ISO Class 0.5 and ASTM Class C standards for higher accuracy.
Features
• Elastic Modulus Measurements within 1 µm Accuracy - Compliant with Elastic Modulus Measurement Requirements of ISO 527, JIS K 7161, and Class B-2 for ASTM D638
• Satisfies Strain Control Requirements of ISO 6892 and JIS Z 2241
Specifications
SSG10-10
Measurement range (mm/FS): 1.0, 0.5, 0.2, 0.1, Four-step selection
Gauge length (mm): 10
Max. measurement range (mm): 1
Max. specimen size (mm): Rod maximum diameter: φ10
Max. specimen size (mm): Flat plate width x thickness: W15xT10
Accuracy: JIS Class 1 ASTM Class CMeasurement range up to 0.3 mm: ± 3 μmMeasurement range above 0.3 mm to max.: ±1.0% of indicated value
Operational temp. range: 5 to 40°C (JIS guaranteed precision range: Fluctuation within ±2°C at 18 to 28°C)
Power Requirements: ESA type amplifier: Single-phase 100 V to 240 V AC at 150 VA (SGX type amplifier requires no power supply.)

SSG25-10
Measurement range (mm/FS): 2.5, 1.25, 0.5, 0.25, Four-step selection
Gauge length (mm): 25
Max. measurement range (mm): 2.5
Max. specimen size (mm): Rod maximum diameter: φ10
Max. specimen size (mm): Flat plate width x thickness: W15xT10
Accuracy: JIS Class 1 ASTM Class CMeasurement range up to 0.3 mm: ± 3 μmMeasurement range above 0.3 mm to max.: ±1.0% of indicated value
Operational temp. range: 5 to 40°C (JIS guaranteed precision range: Fluctuation within ±2°C at 18 to 28°C)
Power Requirements: ESA type amplifier: Single-phase 100 V to 240 V AC at 150 VA (SGX type amplifier requires no power supply.)

SSG50-10
Measurement range (mm/FS): 5, 2.5, 1.0, 0.5, Four-step selection
Gauge length (mm): 50
Max. measurement range (mm): 5
Max. specimen size (mm): Rod maximum diameter: φ15
Max. specimen size (mm): Flat plate width x thickness: W25xT14
Accuracy: Measurement range 0 to 0.13 mm: ±1 μmMeasurement range 0.13 mm to 0.3 mm: ±3 μmMeasurement range 0.3 mm to 5 mm: ±1.0% of indicated value
Operational temp. range: 5 to 40°C (JIS guaranteed precision range: Fluctuation within ±2°C at 18 to 28°C)
Weight: about 75g
Power Requirements: ESA type amplifier: Single-phase 100 V to 240 V AC at 150 VA (SGX type amplifier requires no power supply.)