Le-flex Tubing
| Cat. No. | Specification | Package | Unit | Price | Quantity |
|---|---|---|---|---|---|
| LC01518744-01 | ID x OD (mm): 3.2×6.4; ID x OD (inch): 1/8×1/4 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-02 | ID x OD (mm): 4.8×8.0; ID x OD (inch): 3/16×5/16 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-03 | ID x OD (mm): 6.4×9.6; ID x OD (inch): 1/4×3/8 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-04 | ID x OD (mm): 6.4×11.1; ID x OD (inch): 1/4×7/16 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-05 | ID x OD (mm): 6.4×12.7; ID x OD (inch): 1/4×1/2 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-06 | ID x OD (mm): 9.6×15.9; ID x OD (inch): 3/8×5/8 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-07 | ID x OD (mm): 12.7×19.1; ID x OD (inch): 1/2×3/4 | 15 m/volume, double packing | Each | Inquiry |
|
| LC01518744-08 | ID x OD (mm): 19.1×25.4; ID x OD (inch): 3/4×1 | 4.5 m/volume, double packing | Each | Inquiry |
|
Product Description
Product Description
Le-Flex tubing is specifically designed to meet the requirements of biologics application and has excellent sealing and sterile welding capabilities to ensure the sealing of sterile systems.
Specifications
Test standard: ASTM D412
Test item: 100% of stress at definite elongation
Test result (Pre-gamma radiation): 1.9 MPa
Test result (Post-gamma radiation): 1.6 MPa
Test standard: ASTM D412
Test item: 300% of stress at definite elongation
Test result (Pre-gamma radiation): 3.5 MPa
Test result (Post-gamma radiation): 3.3 MPa
Test standard: ASTM D412
Test item: 300% of tensile set
Test result (Pre-gamma radiation): 0.12
Test result (Post-gamma radiation): 0.16
Test standard: ASTM D746
Test item: Brittleness temperature Test
Test result (Pre-gamma radiation): -70°C
Test result (Post-gamma radiation): -66°C
Test standard: ASTM D395
Test item: Compression set "B" (22hrs, 70°C)
Test result (Pre-gamma radiation): 0.61
Test result (Post-gamma radiation): 0.63
Test standard: ASTM D412
Test item: Elongation at Break
Test result (Pre-gamma radiation): 7.58
Test result (Post-gamma radiation): 7.53
Test standard: ASTM D2440
Test item: Hardness
Test result (Pre-gamma radiation): 59-61 ShoreA
Test result (Post-gamma radiation): 57-59 ShoreA
Test standard: ASTM D624
Test item: Tear strength
Test result (Pre-gamma radiation): 30 KN/m
Test result (Post-gamma radiation): 29.8 KN/m
Test standard: ASTM D412
Test item: Tensile strength
Test result (Pre-gamma radiation): 14.5 MPa
Test result (Post-gamma radiation): 12.6 MPa
Test item: 100% of stress at definite elongation
Test result (Pre-gamma radiation): 1.9 MPa
Test result (Post-gamma radiation): 1.6 MPa
Test standard: ASTM D412
Test item: 300% of stress at definite elongation
Test result (Pre-gamma radiation): 3.5 MPa
Test result (Post-gamma radiation): 3.3 MPa
Test standard: ASTM D412
Test item: 300% of tensile set
Test result (Pre-gamma radiation): 0.12
Test result (Post-gamma radiation): 0.16
Test standard: ASTM D746
Test item: Brittleness temperature Test
Test result (Pre-gamma radiation): -70°C
Test result (Post-gamma radiation): -66°C
Test standard: ASTM D395
Test item: Compression set "B" (22hrs, 70°C)
Test result (Pre-gamma radiation): 0.61
Test result (Post-gamma radiation): 0.63
Test standard: ASTM D412
Test item: Elongation at Break
Test result (Pre-gamma radiation): 7.58
Test result (Post-gamma radiation): 7.53
Test standard: ASTM D2440
Test item: Hardness
Test result (Pre-gamma radiation): 59-61 ShoreA
Test result (Post-gamma radiation): 57-59 ShoreA
Test standard: ASTM D624
Test item: Tear strength
Test result (Pre-gamma radiation): 30 KN/m
Test result (Post-gamma radiation): 29.8 KN/m
Test standard: ASTM D412
Test item: Tensile strength
Test result (Pre-gamma radiation): 14.5 MPa
Test result (Post-gamma radiation): 12.6 MPa
Applications
Application Description
· Sterile disconnection and connection
· Pre-assembly for single-use system
· Preparation of culture medium and buffer solution
· Cells culture and fermentation
· Pre-assembly for single-use system
· Preparation of culture medium and buffer solution
· Cells culture and fermentation
Related Products
Online Inquiry
Note: If you don't receive our verification email, do the following:
- Confirm that you entered your email address correctly.
- Check if the email is in your spam or junk folder.
- Or you may contact us at .