LCMS-2050 Single Quadrupole LC/MS, Polarity Switching Time: 10 msec.
Compact, user-friendly LCMS solution enhances detection & speeds analysis.
| Cat. No. | Specification | Unit | Price | Quantity |
|---|---|---|---|---|
| C002503287-01 | Scan speed: Max 15,000 u/sec | EA | Inquiry |
|
Product Description
Product Description
The space-saving LCMS-2050 is engineered for seamless operation, so you can achieve reliable results with ease and convenience.
The LCMS-2050 single quadrupole mass spectrometer combines the user friendliness of an LC detector with the performance of MS to provide a complete, streamlined, cost-efficient analytical solution.
The system enables enhanced detection in a short period of time because the ionization source combines heated electrospray (HESI) and atmospheric pressure chemical ionization (APCI). This combined dual ion source (DUIS) can analyze a wide range of compounds from multiple chemical classes.
The LCMS-2050 single quadrupole mass spectrometer combines the user friendliness of an LC detector with the performance of MS to provide a complete, streamlined, cost-efficient analytical solution.
The system enables enhanced detection in a short period of time because the ionization source combines heated electrospray (HESI) and atmospheric pressure chemical ionization (APCI). This combined dual ion source (DUIS) can analyze a wide range of compounds from multiple chemical classes.
Features
• Flexible combined dual ion source for enhanced detection
• Small size for space and energy savings
• Easy parameter settings for simplified MS and LC operation
• Analysis of a wide range of compounds from high to low polarity
• Easy maintenance to maximize instrument uptime
• LabSolutions LCMS workstation software to simultaneously control the LC & MS instruments
• Mass-it function automatically adds MS results to UV chromatograms
• Small size for space and energy savings
• Easy parameter settings for simplified MS and LC operation
• Analysis of a wide range of compounds from high to low polarity
• Easy maintenance to maximize instrument uptime
• LabSolutions LCMS workstation software to simultaneously control the LC & MS instruments
• Mass-it function automatically adds MS results to UV chromatograms
Specifications
Mass range: m/z 2 to 2,000
Mass Resolution: 0.7 u
Scan speed: Max. 15,000 u/sec
Polarity switching time: 10 msec.
Mass Resolution: 0.7 u
Scan speed: Max. 15,000 u/sec
Polarity switching time: 10 msec.