HperUC-Lab01 Tangential Flow Filtration System

Cat. No. Dimensions (WxDxH) Specification Unit Price Quantity
FS01531092-01 920*600*650 mm Recommended Maximum Flow Rate for Main Control Integrated Pump: 500 mL/min (with matching tubing) Each Inquiry

Add to Cart

Product Description
Product Description
The Hyper Series Laboratory Filtration System provides a comprehensive laboratory filtration solution, covering processes such as depth filtration, tangential flow filtration, microfiltration, and nanofiltration. It features advanced automation and intelligent design, offering customers a completely new user experience.
Features
· Minimum Hold-up Volume: 5 mL, Maximum Processing Volume: 5 L
· Compatible with: Standard flat-sheet membrane modules and hollow fiber columns with surface areas from 50 cm² to 0.3 m²
· Supports: Both reusable and fully single-use applications
· TMP Control Accuracy: ±0.05 bar / ±1 psi
· Fully Automated Liquid Exchange Dynamic Balance: ±1 g
· All-Domestic Solution: Reliable quality assurance
Specifications
Hardware Configuration Details
· Device Parameters:
Operating Temperature & Humidity: 0–40°C, ≤90%
Dimensions: 920 × 600 × 650 mm; 25 kg
Power Supply: 220 VAC ±10%, 50 Hz
· Sample Stirring Balance:
Range: 0–6200 g
Accuracy: 0.1 g
Stirring Speed: 0–500 rpm
Quantity: 1 unit
· Filtrate Balance:
Range: 0–20000 g
Accuracy: 0.1 g
Quantity: 1 unit
· Main Control Integrated Pump:
Speed Range: 0–650 rpm
Recommended Maximum Flow Rate: 500 mL/min (with matching tubing)
Compatible Tubing Sizes: #13, #14, #16, #19
Roller Material: 316L Stainless Steel
Maximum Inlet Pressure: 3 bar
Quantity: 1 unit
· Auxiliary Refill Pump:
Speed Range: 0–350 rpm
Maximum Flow Rate: 500 mL/min (with matching tubing)
Quantity: 1 unit
· Pressure Sensors:
Range: 0–5.00 bar
Accuracy: 0.01 bar
Material: PES
Connection: Luer male/female
Quantity: 3 units
· Automatic Backpressure Valve:
Stroke: 7 mm
Quantity: 1 unit
· Controller:
Brand: HUAWEI Matebook E
Specs: i7, 16 GB RAM, 1 TB SSD

Optional Accessories:
· Conductivity Detector: Range: 0–300 mS/cm; Accuracy: ±2%; Resolution: 0.001 mS/cm; Quantity: 1 unit
· pH Detector: Range: 0–14 pH; Accuracy: ±0.1 pH; Resolution: 0.1 pH; Quantity: 1 unit
· 60 LH Four-Head Diaphragm Pump: Maximum Flow Rate: 60 L/h; Accuracy: ±2%
· YZ15 Series Peristaltic Pump Heads: Recommended Maximum Flow Rate: 1000 mL/min; Compatible Tubing: #13, #14, #16, #17, #18, #19, #25

Control Software:
· UnitMOD-HyperUC+
· Displays sample flow rate, filtrate flow rate, inlet pressure, recirculation pressure, filtrate pressure, differential pressure, TMP, real-time conductivity and pH
· Monitors shear rate, concentration factor, volume, liquid exchange volume and factor
· Flexible data acquisition timing and intervals
· Supports automated method operation
· Fully compliant with 21 CFR Part 11, including audit trail, access control, role assignment, and data integrity

Control Methods:
· Constant inlet flow rate with TMP control
· Constant recirculation flow rate with TMP control
· TMP regulation time: ≤1 min
· TMP control accuracy: ±1 psi
· Constant-volume liquid exchange accuracy: ±1 g

Control Alarms:
· Three pressure alarms
· Balance weight alarm

Value-Added Services:
· IOQ validation service
· Installation accessory kit: 1 set of #16 tubing, 3 sets of Luer connectors, 1 set of rollers
· Installation and training service
Applications
Application Description
The HyperUC Series Tangential Flow Filtration System is designed for small-volume, high-concentration applications at laboratory and R&D scale. It provides robust ultrafiltration for cell culture, purification, and formulation development, enabling precise process control and comprehensive documentation.