Electromagnetic Force Fatigue and Endurance Testing System
| Cat. No. | Specification | Unit | Price | Quantity |
|---|---|---|---|---|
| MTI1503238-01 | Maximum test force: ±1 kN (static and dynamic tests), Stroke: ±50mm | EA | Inquiry |
|
| MTI1503238-02 | Maximum test force: Dynamic±5kN, Static±3.5kN, Stroke: ±30mm | EA | Inquiry |
|
| MTI1503238-03 | Maximum test force: Dynamic±5kN, Static±3.5kN, Stroke: ±50mm | EA | Inquiry |
|
| MTI1503238-04 | Maximum test force: ±1 kN (static and dynamic tests), Stroke: ±30mm | EA | Inquiry |
|
Product Description
Product Description
High-speed repeated load tests can be carried out with a maximum velocity of 2 m/s, and maximum stroke of ±50 mm, using clean and quiet electromagnetic force as the driving power, without the use of oil. The test space is large so environmental tests can also be carried out using the constant temperature tank (option).
Features
• Fatigue and Endurance Testing Machine with Direct Electrically Powered Actuator
• Allows Long Stroke Lengths and Fast and Highly Accurate Testing in a Clean Environment
• Allows Long Stroke Lengths and Fast and Highly Accurate Testing in a Clean Environment
Specifications
EMT-1kNV-50
Maximum test force: ±1 kN (static and dynamic tests)
Stroke: ±50mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 2m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 510 kg Power amplifier: 60 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60 Hz, 3-phase, 200 V, 5 kVA
Power consumption at max load: 5kW
EMT-5kNV-30
Maximum test force: Dynamic±5kN, Static±3.5kN
Stroke: ±30mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 1100 kg Power amplifier: 300 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60Hz 3-phase 200V 9kVA, Single-phase 100V 300VA
Power consumption at max load: 5kW
EMT-5kNV-50
Maximum test force: Dynamic±5kN, Static±3.5kN
Stroke: ±50mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 100Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 1100 kg Power amplifier: 300 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60Hz 3-phase 200V 9kVA, Single-phase 100V 300VA
Power consumption at max load: 6kW
EMT-1kNV-30
Maximum test force: ±1 kN (static and dynamic tests)
Stroke: ±30mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 510 kg Power amplifier: 60 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60 Hz, 3-phase, 200 V, 4 kVA
Power consumption at max load: 4kW
Maximum test force: ±1 kN (static and dynamic tests)
Stroke: ±50mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 2m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 510 kg Power amplifier: 60 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60 Hz, 3-phase, 200 V, 5 kVA
Power consumption at max load: 5kW
EMT-5kNV-30
Maximum test force: Dynamic±5kN, Static±3.5kN
Stroke: ±30mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 1100 kg Power amplifier: 300 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60Hz 3-phase 200V 9kVA, Single-phase 100V 300VA
Power consumption at max load: 5kW
EMT-5kNV-50
Maximum test force: Dynamic±5kN, Static±3.5kN
Stroke: ±50mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 100Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 1100 kg Power amplifier: 300 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60Hz 3-phase 200V 9kVA, Single-phase 100V 300VA
Power consumption at max load: 6kW
EMT-1kNV-30
Maximum test force: ±1 kN (static and dynamic tests)
Stroke: ±30mm
Cycle speed and amplitude: See amplitude characteristics charts.
Max. speed: 1m/s
Max. frequency: 200Hz
Controller: Servo Controller 4830
Controlled items: Test force and stroke (two can be added as option)
Test force range and indication accuracy: Rangeless Within ±0.5 % of indicated value or ±0.02 % of maximum test force
Stroke range and indication accuracy: Rangeless Within ±1 % of indicated value or ±0.1 % of rated value
Frame drive mechanism: Electric
Test space: Distance between columns: 460 mm Jig mounting spacing: 0 to 700 mm
Weight: Main unit: 510 kg Power amplifier: 60 kg Controller: 8 kg
Operating noise: 62 dB (reference value measured 1 m from front of main unit and floor)
Power Requirements: 50/60 Hz, 3-phase, 200 V, 4 kVA
Power consumption at max load: 4kW
Related Products
Online Inquiry
Note: If you don't receive our verification email, do the following:
- Confirm that you entered your email address correctly.
- Check if the email is in your spam or junk folder.
- Or you may contact us at .