Diamond Phenyl Mustang - Phenyl HIC Chromatography Columns

Cat. No. Specification Unit Price Quantity
CC02502308-01 EzFast Phenyl Mustang Prepacked column 1×1mL Inquiry
CC02502308-02 EzFast Phenyl Mustang Prepacked column 5×1mL Inquiry
CC02502308-03 EzFast Phenyl Mustang Prepacked column 1×5mL Inquiry
CC02502308-04 EzFast Phenyl Mustang Prepacked column 5×5mL Inquiry
CC02502308-05 EzScreen Phenyl Mustang Prepacked column 1×4.6mL Inquiry
CC02502308-06 EzScreen Phenyl Mustang Prepacked column 5×4.6mL Inquiry
CC02502308-07 EzLoad 16/10 Phenyl Mustang Prepacked column 1 pcs Inquiry
CC02502308-08 EzLoad 26/10 Phenyl Mustang Prepacked column 1 pcs Inquiry

Add to Cart

Product Description
Product Description
Hydrophobic interaction chromatography (HIC) is a chromatographic method that uses the interaction between the hydrophobic groups carried by biological molecules and the hydrophobic ligands on the stationary phase to separate substances. Salt ions can destroy the hydration membrane on the surface of biomolecules and promote the binding between hydrophobic groups and ligands.
Diamond Phenyl Mustang is based on fine particle high-rigidity agarose with a hydrophobic phenyl group. The high resolution and low back pressure are suitable for the intermediate purification stage and fine purification stage of protein downstream purification.
Specifications

Appearance

White slurry

Matrix

Highly cross-linked agarose

Functional group

Phenyl

Average particle size

36~44μm

Hydrophobicity

The retention time of Lyzosyme is 45-50min

Dynamic binding capacity

~19mg BSA/mL packed resin

Max. pressure

0.5MPa

Pressure flow velocity

≥450cm/h(0.5MPa BXK 100/500, H=20cm, 20°C)

Chemical stability

Stable in common aqueous buffers: 2M NaOH+,0.5M NaOH+,1M HAc+, 6M GuHCl,8M Urea,30% isopropyl alcohol,30% acetonitrile,2%SDS,3M(NH4)2SO4+ 0.1M KH2PO4(pH7.0)

pH stability

2~14(CIP),3~13(working)

Operating temperature

Operating temperature: 2~40°C, do not freeze, Can tolerate 121°C high pressure sterilization (20min)

Storage++

2~30°C, 20% ethanol or 2% benzyl alcohol

Recommended flow velocity

90~180cm/h

+1M NaOH and 1M HAc only be used for cleaning.
++ 2% benzyl alcohol is only used for international transport or special requirements from customer.