AirPrep™ Pitt120V Aerosol Generator
| Cat. No. | Description | Unit | Price | Quantity |
|---|---|---|---|---|
| LEA1560098-01 | Fluidized bed aerosol generator with a remote amplifier and flow controller. | Each | Inquiry |
|
Product Description
Product Description
The PITT120V Aerosol Generator offers consistent and reliable aerosol production across a wide range of powder materials, including biological, chemical, and pharmaceutical powders. Engineered for exceptional precision and versatility, the PITT120V Aerosol Generator is ideal for both research and industrial environments.
This advanced fluidized bed aerosol generator builds upon the trusted design of Weyel's original PITT-3, now with improved precision and flexibility. Equipped with an integrated Control Unit, it enables remote operation and seamless integration into diverse testing setups, including enclosed aerosol chambers. Capable of aerosolizing various particulates—both biological and non-biological—the PITT120V Aerosol Generator is a versatile and essential tool in aerosol research and development.
This advanced fluidized bed aerosol generator builds upon the trusted design of Weyel's original PITT-3, now with improved precision and flexibility. Equipped with an integrated Control Unit, it enables remote operation and seamless integration into diverse testing setups, including enclosed aerosol chambers. Capable of aerosolizing various particulates—both biological and non-biological—the PITT120V Aerosol Generator is a versatile and essential tool in aerosol research and development.
Features
· Versatile Powder Handling: Processes a wide range of powders, from fine biological agents to coarse chemical compounds, ensuring compatibility with diverse materials.
· Precision Control: Offers fine-tuned control over aerosolization parameters, including particle size, concentration, and flow rate, to meet specific experimental needs.
· Stable Aerosol Output: Fluidized bed design delivers consistent, homogeneous aerosols, essential for repeatable and accurate testing in various applications.
· Rugged Construction: Engineered for durability with industrial-grade build and fan-cooled electronics, ideal for continuous operation in demanding environments.
· Flexible Integration: Compatible with various signal generators and adaptable for near-vacuum operations, allowing for customizable and versatile use.
· Easy Maintenance: Features tool-free removal of components for quick reloading and decontamination, minimizing downtime.
· Remote Operation: Control unit enables remote adjustments of flow rate and amplitude, enhancing flexibility in different testing setups
· Precision Control: Offers fine-tuned control over aerosolization parameters, including particle size, concentration, and flow rate, to meet specific experimental needs.
· Stable Aerosol Output: Fluidized bed design delivers consistent, homogeneous aerosols, essential for repeatable and accurate testing in various applications.
· Rugged Construction: Engineered for durability with industrial-grade build and fan-cooled electronics, ideal for continuous operation in demanding environments.
· Flexible Integration: Compatible with various signal generators and adaptable for near-vacuum operations, allowing for customizable and versatile use.
· Easy Maintenance: Features tool-free removal of components for quick reloading and decontamination, minimizing downtime.
· Remote Operation: Control unit enables remote adjustments of flow rate and amplitude, enhancing flexibility in different testing setups
Applications
Application Description
The Pitt120V supports controlled aerosol generation for studies requiring repeatable dry dissemination of powders, fibers, and particulate materials. It can be integrated into aerosol chambers, enclosed test systems, and custom R&D setups where researchers need to evaluate aerosol behavior, sampler performance, particle recovery, collection efficiency, or downstream detection workflows.
Common uses include:
· Aerosol sampler evaluation and comparison
· Bioaerosol and particulate collection studies
· Dry powder and fiber dissemination studies
· Chamber-based aerosol research
· Environmental biosurveillance method development
· Industrial hygiene and exposure simulation
· Government, defense, and applied research programs
· Pharmaceutical or specialty powder aerosolization studies
Common uses include:
· Aerosol sampler evaluation and comparison
· Bioaerosol and particulate collection studies
· Dry powder and fiber dissemination studies
· Chamber-based aerosol research
· Environmental biosurveillance method development
· Industrial hygiene and exposure simulation
· Government, defense, and applied research programs
· Pharmaceutical or specialty powder aerosolization studies